11. Disconnect the power connector from the control panel to the power sup-
ply. Refer to Figure 4-23.
12. Remove the three (3) hex screws that secure the power supply to the elec-
tronic enclosure shelf. Refer to Figure 4-23.
13. Slide the power supply out of the electronics enclosure while passing the
power connector and fan wires through the holes provided in the electron-
ics enclosure.
Replace:
1. Reverse the removal procedure to re-install the power supply.
2. Turn the system on and check for proper operation.

4.4.6 Main Power Switch

Tools Required: Pliers, 1/4" nut driver
Remove:
1. Remove the operator control panel. See Section 4.4.3, Operator Control
Panel Assembly.
NOTE: You do not have to save the customer user parameters if
only the power switch is being replaced.
4-36 Removal and Replacement