Avantra 36/44 Service Manual
4. Beginning directly under the shuttle motor and working downward, tie
wrap the bridge cables (include the interface platen cable).
5. Feed the cable bundle through the rubber grommet in the access hole.
The access hole is located in the imagesetter frame below the access plate.
6. Wrap the wires under the shuttle motor into a P-clamp. Using a hex screw
and two (2) star lock washers, secure the clamp to the bridge support cast-
ing.
7. Attach Velcro mesh wrap around the cables before they enter the rubber
grommet and where they hang near the system casting.
8. Install the bridge connectors to the bridge/buffer board using the wire and
plug designations shown in Figure 1-21.
9. Using the four (4) sems screws provided, attach the bridge/buffer housing
cover (see Figure 1-19).
Cable Bundle 666919-1554
Cable Bundle 66919-1424
Cable Bundle 66919-1324
Cable Bundle 6696-0021
Cable Bundle 66696-0319
Cable Bundle 66919-1323
Figure 1-21 Attaching the connectors to the bridge/buffer interface board.
–Bridge/buffer interface board. –Dec to bridge/buffer interface cable.
1-20
Installation
J3
J4
J7
Empty
J10
1
2
J2
J1
J9
Cable Bundle 66695-127
J8
J5
Cable Bundle 208840-506
J6