System-Monitor Enable - 3Com Switch 4500 Family Manual

4500 series
Hide thumbs Also See for Switch 4500 Family:
Table of Contents

Advertisement

After you execute the command, the system will prompt you to confirm. Enter "Y" or "y" for your setting
to take effect. Your setting will overwrite the previous one (if available).
If you adjust the system time by the clock command after executing the schedule reboot regularity
command, the configured schedule reboot regularity command will be invalid.
Related commands: reboot, schedule reboot at, undo schedule reboot, display schedule reboot.
Examples
# Schedule a reboot so that the switch reboots at 10:00 every Thursday.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] schedule reboot regularity at 10:00 thursday
Schedule reboot regularity, are you sure?[Y/N]:y
[Sysname]

system-monitor enable

Syntax
system-monitor enable
undo system-monitor enable
View
System view
Parameters
None
Description
Use the system-monitor enable command to enable real-time monitoring of the running status of the
system.
Use the undo system-monitor enable command to disable real-time monitoring of the running status
of the system.
This function enables you to dynamically record the system running status, such as CPU, thus
facilitating analysis and solution of the problems of the device.
By default, real-time monitoring of the running status of the system is enabled.
Enabling of this function consumes some amounts of CPU resources. Therefore, if your network has a
high CPU usage requirement, you can disable this function to save your CPU resources.
Examples
# Disable real-time monitoring of the running status of the system.
<Sysname> system-view
3-16

Advertisement

Table of Contents
loading

This manual is also suitable for:

4500 26-port4500 50-port4500 pwr 26-port

Table of Contents