01-305 Left Hand Door Open RAP
01-305 The left hand door has been opened during machine operation.
Procedure
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
NOTE: To access the left door interlock, remove the interlock cover, PL 7.30 Item 23.
Enter dC330, code 01-305 left door interlock. Press Start, open and close the left hand door,
Figure 1. The display changes.
Y
N
Go to Flag 1. Check the left hand door interlock, S01-305. Refer to:
•
GP 13, How to Check a Switch.
•
P/J7 on the IOT PWB.
•
01D +3.3V Distribution RAP.
•
01B 0V Distribution RAP
•
Install new components as necessary:
–
Left hand door interlock, PL 7.30 Item 3.
Check that the left hand door closes correctly. If not, check the following:
•
Hinge pin, PL 7.30 Item 8, is located correctly.
•
Left hand door latch, part of the LH door, PL 7.30 Item 2.
•
Check that the interlock cover is not loose, PL 7.30 Item 23. If necessary push the cover
towards the front and tighten the screws.
WorkCentre 5687 Family
Figure 1 Component Location
August 2007
2-9
Left hand door
interlock, S01-305
Status Indicator RAPs