5.11 Holding Brake

5.11.5 Built-in Brake Relay Usage Selection

• When the Time Set In Pn508 Elapses after the Power Supply to the Motor Is Stopped
Controlword
(6040 hex), alarm,
or power OFF
Motor speed
Motor power status
Important

5.11.5 Built-in Brake Relay Usage Selection

SERVOPACKs with built-in brake control contain a brake relay.
Set Pn023 = n.
brake relays.
Pn023
(2023 hex)
5-36
Enable
Operation
Power
supplied.
ON (Brake released.)
/BK signal
Pn508
The Servomotor will be limited to its maximum speed even if the brake reference output speed
level (Rotary Servomotor: Pn507, Linear Servomotor: Pn583) is higher than the maximum speed.

X (Built-in Brake Relay Usage Selection) to specify whether to use the built-in
Parameter

n.
0
Use the built-in brake relays.
(default setting)

n.
1
Do not use the built-in brake relays.
Disable
Operation
Rotary Servomotor: Pn507
Linear Servomotor: Pn583
Motor stopped with dynamic
brake or by coasting
(Pn001 = n.
Power not
supplied.
OFF (Brake applied.)
Description
X)
When Enabled
Classification
After restart
Setup