YASKAWA SGD7S-1R9D Product Manual page 104

Table of Contents

Advertisement

Output Signals
Default settings are given in parentheses.
Signal
Pin No.
ALM+
3
Servo Alarm Output
ALM-
4
*
/SO1+
1
General-purpose
(/BK+)
Sequence Output 1
*
/SO1-
(Brake Output)
2
(/BK-)
/SO2+*
23
General-purpose
Sequence Output 2
/SO2-*
24
/SO3+*
25
General-purpose
Sequence Output 3
/SO3-*
26
/SO4+*
27
General-purpose
Sequence Output 4
/SO4-*
28
/SO5+*
29
General-purpose
Sequence Output 5
/SO5-*
30
PAO
17
Encoder Divided Pulse
Output, Phase A
/PAO
18
PBO
19
Encoder Divided Pulse
Output, Phase B
/PBO
20
PCO
21
Encoder Divided Pulse
Output, Phase C
/PCO
22
SG
16
Signal ground
*
You can change the allocations. Refer to the following section for details.
6.1.2 Output Signal Allocations on page 6-5
4.5.1 I/O Signal Connector (CN1) Names and Functions
Name
Turns OFF (opens) when an error is detected.
You can allocate the output signal to use with
a parameter.
(Controls the brake. The brake is released
when the signal turns ON (closes).)
Used for general-purpose outputs.
Set the parameters to allocate functions.
Output the encoder divided pulse output sig-
nals with a 90° phase differential.
Outputs the origin signal once every encoder
rotation.
This is the 0-V signal for the control circuits.
4.5 Connecting I/O Signals
Function
Reference
page 6-7
page 5-32
page 14-47
page 6-31
page 6-40
4
4-29

Hide quick links: