YASKAWA SGD7S-1R9D Product Manual page 549

Table of Contents

Advertisement

16.1 List of Parameters
16.1.2 List of Parameters
Parameter
No.
Pn00A
(200A hex)
Pn00B
(200B hex)
16-8
Name
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 (2001 hex) = n.X).
Decelerate the motor to a stop using the torque set in Pn406
1
(2406 hex) as the maximum torque. Use the setting of Pn001
(2001 hex) = n.X for the status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406
2
(2406 hex) as the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A (230A hex). Use the setting of Pn001 (2001 hex) =
n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A (230A hex) and then let the motor coast.
Stopping Method for Forced Stops
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 (2001 hex) = n.X).
Decelerate the motor to a stop using the torque set in Pn406
1
(2406 hex) as the maximum torque. Use the setting of Pn001
(2001 hex) = n.X for the status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406
2
(2406 hex) as the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A (230A hex). Use the setting of Pn001 (2001 hex) =
n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A (230A hex) and then let the motor coast.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections B
Operator Parameter Display Selection

n.
X
0
Display only setup parameters.
1
Display all parameters.
Motor Stopping Method for Group 2 Alarms
0
Stop the motor by setting the speed reference to 0.

n.
X
Apply the dynamic brake or coast the motor to a stop (use the
1
stopping method set in Pn001 (2001 hex) = n.X).
2
Set the stopping method with Pn00A (200A hex) = n.X.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000 hex to
0001
0044 hex
hex
0000 hex to
0000
1121 hex
hex
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 5-38
Reference
page 6-55
After
All
Setup
restart
Reference
page 5-3
Reference
page 5-38
Continued on next page.
Refer-
ence

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents