16.1 List of Parameters
16.1.2 List of Parameters
Parameter
No.
Pn00A
(200A hex)
Pn00B
(200B hex)
16-8
Name
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 (2001 hex) = n.X).
Decelerate the motor to a stop using the torque set in Pn406
1
(2406 hex) as the maximum torque. Use the setting of Pn001
(2001 hex) = n.X for the status after stopping.
n.
X
Decelerate the motor to a stop using the torque set in Pn406
2
(2406 hex) as the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A (230A hex). Use the setting of Pn001 (2001 hex) =
n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A (230A hex) and then let the motor coast.
Stopping Method for Forced Stops
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 (2001 hex) = n.X).
Decelerate the motor to a stop using the torque set in Pn406
1
(2406 hex) as the maximum torque. Use the setting of Pn001
(2001 hex) = n.X for the status after stopping.
n.
X
Decelerate the motor to a stop using the torque set in Pn406
2
(2406 hex) as the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A (230A hex). Use the setting of Pn001 (2001 hex) =
n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A (230A hex) and then let the motor coast.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Application Function
2
Selections B
Operator Parameter Display Selection
n.
X
0
Display only setup parameters.
1
Display all parameters.
Motor Stopping Method for Group 2 Alarms
0
Stop the motor by setting the speed reference to 0.
n.
X
Apply the dynamic brake or coast the motor to a stop (use the
1
stopping method set in Pn001 (2001 hex) = n.X).
2
Set the stopping method with Pn00A (200A hex) = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000 hex to
0001
–
0044 hex
hex
0000 hex to
0000
–
1121 hex
hex
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 5-38
Reference
page 6-55
After
All
Setup
restart
Reference
page 5-3
Reference
page 5-38
Continued on next page.
Refer-
ence
–
–