YASKAWA SGD7S-1R9D Product Manual page 353

Table of Contents

Advertisement

7.
Click the Result Writing Button if you want to set the measurement results in the param-
eters.
This concludes the procedure to set up Easy FFT.
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
Easy FFT.
Do not change the settings of these parameters during execution of Easy FFT.
Parameter
Pn408 (2408 hex)
Torque-Related Function Selections
Pn409 (2409 hex)
First Stage Notch Filter Frequency
Pn40A (240A hex)
First Stage Notch Filter Q Value
Pn40C (240C hex) Second Stage Notch Filter Frequency
Pn40D (240D hex)
Second Stage Notch Filter Q Value
Pn456 (2456 hex)
Sweep Torque Reference Amplitude
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Name
Automatic Changes
8.14 Diagnostic Tools
8.14.2 Easy FFT
Yes
Yes
No
Yes
No
No
8