Alarm Code:
Possible Cause
Alarm Name
bF1 hex:
A failure occurred in
the SERVOPACK.
System Alarm 1
bF2 hex:
A failure occurred in
the SERVOPACK.
System Alarm 2
bF3 hex:
A failure occurred in
the SERVOPACK.
System Alarm 3
bF4 hex:
A failure occurred in
System Alarm 4
the SERVOPACK.
The order of phases
U, V, and W in the
motor wiring is not
correct.
There is an error in the
setting of Pn080
(2080 hex) =
n.X
(Motor Phase Selec-
tion).
C10 hex:
Servomotor Out
of Control
(Detected when
the servo is
A failure occurred in
turned ON.)
the encoder.
A failure occurred in
the SERVOPACK.
Confirmation
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Check the Servomotor
Make sure that the Servo-
wiring.
motor is correctly wired.
Check the setting of
Set Pn080 (2080 hex) =
Pn080 (2080 hex) =
n.X to an appropri-
n.X.
ate value.
If the motor wiring is cor-
rect and an alarm still
occurs after turning the
power supply OFF and
ON again, the Servomotor
or linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
15.2 Alarm Displays
15.2.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
page 5-20
Continued on next page.
15