16.1 List of Parameters
16.1.2 List of Parameters
Parameter
No.
Pn583
(2583 hex)
Pn584
(2584 hex)
Pn585
(2585 hex)
Pn586
(2586 hex)
Pn587
(2587 hex)
Pn600
(2600 hex)
Pn601
(2601 hex)
Pn603
(2603 hex)
Pn604
(2604 hex)
PnBA0
(2752 hex)
16-28
Name
Brake Reference Out-
2
put Speed Level
Speed Limit Level at
2
Servo ON
Program Jogging Move-
2
ment Speed
Motor Running Cooling
2
Ratio
Polarity Detection
2
Execution Selection for
Absolute Linear Encoder
Polarity Detection Selection for Absolute Linear Encoder

n.
X
0
Do not detect polarity.
1
Detect polarity.

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Regenerative Resistor
2
*2
Capacity
Dynamic Brake Resis-
2
tor Allowable Energy
Consumption
Regenerative Resis-
2
tance
Dynamic Brake Resis-
2
tance
ZONE Output Signal
2
Selection 1
/ZONE0 (ZONE Signal 1 Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.

n.
X
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4
Output the signal from the CN1-27 or CN1-28 output terminal.
5
Output the signal from the CN1-29 or CN1-30 output terminal.
/ZONE1 (ZONE Signal 2 Output) Signal Allocation

n.
X
The allocations are the same as the /ZONE0 (ZONE Signal 1 Out-
0 to 5
put) signal allocations.
/ZONE2 (ZONE Signal 3 Output) Signal Allocation

n.
X
The allocations are the same as the /ZONE0 (ZONE Signal 1 Out-
0 to 5
put) signal allocations.
/ZONE3 (ZONE Signal 4 Output) Signal Allocation

n.X
The allocations are the same as the /ZONE0 (ZONE Signal 1 Out-
0 to 5
put) signal allocations.
Setting
Setting
Default
Range
Unit
Setting
0 to 10,000
1 mm/s
10
0 to 10,000
1 mm/s
10000
1 to 10,000
1 mm/s
50
1%/
0 to 100
Max.
0
speed
0000 hex to
0000
0001 hex
hex
Depends on
10 W
0
*3
model.
0 to 65,535
10 J
0
0 to 65,535
10 mΩ
0
0 to 65,535
10 mΩ
0
0000 hex to
0000
5555 hex
hex
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Reference
page 5-23
Immedi-
All
Setup
ately
After
All
Setup
restart
Immedi-
All
Setup
ately
After
All
Setup
restart
After
All
Setup
restart
Reference
page 6-60
Reference
page 6-60
Reference
page 6-60
Reference
page 6-60
Continued on next page.
Refer-
ence
page
5-32
page
8-10
page
7-13
page
5-55
page
5-56
page
5-55
page
5-56