8.10 Vibration Suppression
8.10.2 Preparations
8.10.2 Preparations
Check the following settings before you execute vibration suppression.
• Position control must be used.
• The tuning-less function must be disabled (Pn170 = n.0).
• The test without a motor function must be disabled (Pn00C = n.0).
• The parameters must not be write prohibited.
8.10.3 Applicable Tools
The following table lists the tools that you can use to perform vibration suppression and the
applicable tool functions.
Digital Operator
SigmaWin+
8.10.4 Operating Procedure
Use the following procedure to perform vibration suppression.
1.
Perform steps 1 to 7 of the procedure for custom tuning. Refer to the following section
for details.
2.
Click the Vib Suppress Button.
8-56
Tool
Fn205
Tuning - Tuning
8.8.4 Operating Procedure on page 8-42
Function
Operating Procedure Reference
Σ-7-Series Digital Operator Operating Man-
ual (Manual No.: SIEP S800001 33)
8.10.4 Operating Procedure on page 8-56