5.1.4

Write Prohibition Setting for SERVOPACK Parameters

You can prohibit writing SERVOPACK parameters from a Digital Operator. Even if you do, you
will still be able to change SERVOPACK parameter settings from the SigmaWin+ or with Ether-
CAT (CoE) communications.
Preparations
No preparations are required.
Applicable Tools
The following table lists the tools that you can use to change the write prohibition setting for
SERVOPACK parameters and the applicable tool functions.
Tool
Digital Operator
SigmaWin+
Operating Procedure
Use the following procedure to prohibit or permit writing parameters.
1.
Click the
2.
Select Write Prohibition Setting in the Menu Dialog Box.
The Write Prohibition Setting Dialog Box will be displayed.
3.
Press the
0000: Writing is permitted (default setting).
0001: Writing is prohibited.
4.
Click the Setting Button.
Function
Fn010
Setup - Write Prohibited Setting
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
or
for the rightmost digit and set one of the following.
5.1 Manipulating SERVOPACK Parameters (Pn)

5.1.4 Write Prohibition Setting for SERVOPACK Parameters

Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001
33)
Operating Procedure on page 5-7
Reference
5
5-7