13.6 Torque Control Modes

13.6.2 Cyclic Sync Torque Mode

13.6.2 Cyclic Sync Torque Mode
In the Cyclic Synchronous Torque Mode, the master provides the target torque to the Servo
Drive, which performs torque control.
Torque offset (60B2 hex)
Target torque (6071 hex)
Max torque (6072 hex)
Torque limit values (60E0 hex and 60E1 hex)
Torque actual value (6077 hex)
Velocity actual value (606C hex)
Position actual value (6064 hex)
Related Objects
Index
6071 hex
6074 hex
6077 hex
60B2 hex
6072 hex
60E0 hex
60E1 hex
*
The rated motor torque is 100%.
13-20
+
+
Torque
limit
function
Multiplier
Velocity
user unit
(2702 hex: 1, 2702 hex: 2)
Position actual
internal value (6063 hex)
Position
user unit
(2701 hex: 1, 2701 hex: 2)
Subindex
Name
0
Target torque
0
Torque demand value
0
Torque actual value
0
Torque offset
0
Max torque
0
Positive torque limit value
0
Negative torque limit value
Torque
demand
value
(6074 hex)
Torque
control
Encoder
Access
RW
RO
RO
RW
RW
RW
RW
Motor
PDO
Data
Unit
Mapping
Type
Yes
0.1%*
INT
Yes
0.1%*
INT
Yes
0.1%*
INT
Yes
0.1%*
INT
Yes
0.1%*
UINT
Yes
0.1%*
UINT
Yes
0.1%*
UINT