16.1 List of Parameters
16.1.2 List of Parameters
Parameter
No.
Pn022
(2022 hex)
Pn023
(2023 hex)
Pn040
(2040 hex)
Pn080
(2080 hex)
16-10
Name
Application Function
2
Selections 22
Overtravel Release Method Selection
0
Overtravel exists while the P-OT or N-OT signal is being input.
n.
X
Overtravel exists while the P-OT or N-OT signal is input and the
1
current position of the workpiece is separated from the P-OT sig-
nal or N-OT signal.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Application Function
2
Selections 23
n. X
Built-in Brake Relay Usage Selection
0
Use the built-in brake relay.
1
Do not use the built-in brake relay.
n. X
Reserved parameter (Do not change.)
n. X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Reserved parameter (Do
2
not change.)
Application Function
2
Selections 80
Polarity Sensor Selection
n.
X
0
Use polarity sensor.
1
Do not use polarity sensor.
Motor Phase Sequence Selection
n.
X
0
Set a phase-A lead as a phase sequence of U, V, and W.
1
Set a phase-B lead as a phase sequence of U, V, and W.
n.
X
Reserved parameter (Do not change.)
Calculation Method for Maximum Speed or Encoder Output Pulses
Calculate the encoder output pulse setting for a fixed maximum
0
n.X
speed.
Calculate the maximum speed for a fixed encoder output pulse
1
setting.
Setting
Setting
Default
Range
Unit
Setting
0000 hex to
0000
–
0011 hex
hex
0000 hex to
0000
–
0001 hex
hex
0000 hex to
0000
–
2111 hex
hex
0000 hex to
0000
–
1111 hex
hex
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 5-30
After
All
Setup
restart
Reference
page 5-30
–
–
–
After
Linear
Setup
restart
Reference
page 5-22
Reference
page 5-20
Reference
page 17-6
Continued on next page.
Refer-