YASKAWA SGD7S-1R9D Product Manual page 445

Table of Contents

Advertisement

14.4 Sync Manager Communications Objects
Sync Manager Synchronization (1C32 Hex and 1C33 Hex)
 Sync Manager 2 (Process Data Output) Synchronization
Index
1C32 hex
14-14
Subin-
Name
dex
Number of synchroni-
0
zation parameters
1
Synchronization type
2
Cycle time
3
Shift time
Synchronization types
4
supported
5
Minimum cycle time
6
Calc and copy time
7
Reserved
8
Reserved
9
Delay time
10
Sync0 cycle time
11
Reserved
12
SM2 event miss count
Data
PDO
Access
Type
Mapping
USINT
RO
No
UINT
RO
No
UDINT
RO
No
UDINT
RO
No
UINT
RO
No
UDINT
RO
No
UDINT
RO
No
UDINT
RO
No
UINT
RO
No
UDINT
RO
No
UDINT
RO
No
UDINT
RO
No
UDINT
RO
No
Saving to
Value
EEPROM
10
No
0: Free-Run
(DC not used)
No
2: DC Sync0
(DC used)
Sync0 event cycle
No
[ns]
125,000 [ns]
No
Bit 0 = 1: Free-Run
supported
Bits 2 to 4 = 001:
DC Sync0 sup-
No
ported
Bits 5 and 6 = 00:
Output shift not
supported.
62,500 [ns]
No
62,500 [ns]
No
No
No
0 [ns]
No
Same as 1C32 hex:
No
02.
No
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents