11.2 Hard Wire Base Block (HWBB and SBB)

11.2.1 Risk Assessment

11.2

Hard Wire Base Block (HWBB and SBB)

A hard wire base block (abbreviated as HWBB) is a safety function that is designed to shut OFF
the current to the motor with a hardwired circuit.
The drive signals to the Power Module that controls the motor current are controlled by the cir-
cuits that are independently connected to the two input signal channels to turn OFF the Power
Module and shut OFF the motor current.
Important
The input signal uses the 0-V common. The following figure shows a connection example.
24-V power supply
Fuse
0 V

11.2.1 Risk Assessment

When using the HWBB, you must perform a risk assessment of the Servo System in advance
to confirm that the safety level of the standards is satisfied. Refer to the following section for
details on the standards.
Compliance with UL Standards, EU Directives, and Other Safety Standards on page xxii
Note: To meet performance level e (PLe) in EN ISO 13849-1 and SIL3 in IEC 61508, the EDM1 signal must be mon-
itored by the host controller. If the EDM1 signal is not monitored by the host controller, the level will be safety
performance level c (Plc) and SIL1.
The following hazards exist even when the HWBB is operating. These hazards must be
included in the risk assessment.
• The Servomotor will move if an external force is applied to it (for example, gravity on a vertical
axis). Implement measures to hold the Servomotor, such as installing a separate mechanical
brake.
11-4
For safety function signal connections, the input signal is the 0-V common and the output signal
is a source output.
This is opposite to other signals described in this manual.
To avoid confusion, the ON and OFF status of signals for the safety function are defined as fol-
lows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows
into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current
flows into the signal line.
CN8
Switch
/HWBB1+ 4
/HWBB1-
3
/HWBB2+
/HWBB2-
5
SERVOPACK
Control circuit
Stopped.
Stopped.
Power supply
Power Module