YASKAWA SGD7S-1R9D Product Manual page 56

Table of Contents

Advertisement

Item
Inputs
Output
Safety
Functions
Applicable
*4
Standards
Applicable Option Modules
If you combine a Σ-7-Series SERVOPACK with a Σ-V-Series Option Module, the surrounding air temperature
*1.
specification of the Σ-V-Series SERVOPACKs must be used, i.e., 0°C to 55°C. Also, the applicable surrounding
range cannot be increased by derating.
*2.
The coefficient of speed fluctuation for load fluctuation is defined as follows:
Coefficient of speed fluctuation = No-load motor speed - Total-load motor speed
*3.
The SGD7S-210D, -260D, -280D, and -370D do not have a dynamic brake (DB). If a dynamic brake is neces-
sary, create an external dynamic brake circuit.
*4.
Always perform risk assessment for the system and confirm that the safety requirements are met.
/HWBB1 and /HWBB2: Base block signals for Power Modules
EDM1: Monitors the status of built-in safety circuit (fixed output).
ISO13849-1 PLe (category 3), IEC61508 SIL3
Fully-closed Modules
Rated motor speed
2.1 Ratings and Specifications
2.1.3 Specifications
Continued from previous page.
Specification
×
100%
2
2-7