YASKAWA SGD7S-1R9D Product Manual page 82

Table of Contents

Advertisement

Noise Filter Wiring and Connection Precautions
Always observe the following precautions when wiring or connecting Noise Filters.
• Separate input lines from output lines. Do not place input lines and output lines in the same
duct or bundle them together.
Incorrect
Noise
Filter
Grounding plate
Noise
Filter
Grounding plate
• Separate the Noise Filter ground wire from the output lines. Do not place the Noise Filter
ground wire, output lines, and other signal lines in the same duct or bundle them together.
Incorrect
Noise
Filter
Grounding plate
• Connect the Noise Filter ground wire directly to the grounding plate. Do not connect the
Noise Filter ground wire to other ground wires.
Incorrect
Noise
Filter
SERVOPACK SERVOPACK
Shielded ground wire
Grounding plate
Correct
Noise
Filter
Grounding plate
Noise
Filter
Grounding
plate
Separate the circuits.
Correct
Noise
Filter
It is OK if the ground
wire is close to the
input lines.
Grounding plate
Correct
Noise
Filter
SERVOPACK SERVOPACK
Grounding plate
4.1 Wiring and Connecting SERVOPACKs
4.1.2 Countermeasures against Noise
4
4-7