R&S FSW-K7 User Manual page 359

Analog demodulation measurement option
Table of Contents

Advertisement

®
R&S
FSW-K7
Compared to shifting the limit line, an offset does not actually change the limit line defi-
nition points.
Suffix:
<n>
<k>
Parameters:
<Offset>
Manual operation:
CALCulate<n>:LIMit<k>:LOWer:SHIFt <Distance>
This command moves a complete lower limit line vertically.
Compared to defining an offset, this command actually changes the limit line definition
points by the value you define.
Suffix:
<n>
<k>
Parameters:
<Distance>
Manual operation:
CALCulate<n>:LIMit<k>:LOWer:SPACing <InterpolType>
This command selects linear or logarithmic interpolation for the calculation of a lower
limit line from one horizontal point to the next.
Suffix:
<n>
<k>
Parameters:
<InterpolType>
Manual operation:
CALCulate<n>:LIMit<k>:LOWer:STATe <State>
This command turns a lower limit line on and off.
User Manual 1173.9240.02 ─ 23
Remote Commands for Analog Demodulation Measurements
.
Window
Limit line
Numeric value.
*RST:
0
Default unit: dB
See
"Y-Offset"
on page 157
.
Window
Limit line
Defines the distance that the limit line moves.
The unit depends on
on page 360.
See
"Shift y"
on page 160
.
Window
Limit line
LINear | LOGarithmic
*RST:
LIN
See
"Y-Axis"
on page 159
CALCulate<n>:LIMit<k>:UNIT
Analyzing Results
359

Advertisement

Table of Contents
loading

Table of Contents