R&S FSW-K7 User Manual page 333

Analog demodulation measurement option
Table of Contents

Advertisement

®
R&S
FSW-K7
CALCulate<n>:MARKer<m>:SGRam:Y:MINimum:NEXT
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MINimum:NEXT
This command moves a marker vertically to the next higher minimum level for the cur-
rent frequency.
The search includes all frames. It does not change the horizontal position of the
marker.
Suffix:
<n>
<m>
Usage:
CALCulate<n>:MARKer<m>:SGRam:Y:MINimum[:PEAK]
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MINimum[:PEAK]
This command moves a marker vertically to the minimum level for the current fre-
quency.
The search includes all frames. It does not change the horizontal position of the
marker.
If the marker hasn't been active yet, the command first looks for the peak level for all
frequencies and moves the marker vertically to the minimum level.
Suffix:
<n>
<m>
Usage:
Using Delta Markers
The following commands control spectrogram delta markers.
Useful commands for spectrogram markers described elsewhere
The following commands define the horizontal position of the delta markers.
CALCulate<n>:DELTamarker<m>:MAXimum:LEFT
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK]
CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt
CALCulate<n>:DELTamarker<m>:MINimum:LEFT
CALCulate<n>:DELTamarker<m>:MINimum:NEXT
CALCulate<n>:DELTamarker<m>:MINimum[:PEAK]
CALCulate<n>:DELTamarker<m>:MINimum:RIGHt
User Manual 1173.9240.02 ─ 23
Remote Commands for Analog Demodulation Measurements
.
Window
Marker
Event
.
Window
Marker
Event
Analyzing Results
on page 341
on page 342
on page 342
on page 342
on page 342
on page 343
on page 343
on page 343
333