R&S FSW-K7 User Manual page 240

Analog demodulation measurement option
Table of Contents

Advertisement

®
R&S
FSW-K7
DIAGnostic:SERVice:NSOurce <State>
This command turns the 28 V supply of the BNC connector labeled NOISE SOURCE
CONTROL on the R&S FSW on and off.
Suffix:
<n>
Parameters:
<State>
Example:
Manual operation:
OUTPut:ADEMod[:ONLine][:STATe] <State>
This command enables or disables online demodulation output to the IF/VIDEO/
DEMOD output connector on the rear panel of the R&S FSW.
Parameters:
<State>
Example:
Manual operation:
OUTPut:ADEMod[:ONLine]:SOURce <WindowName>
This command selects the result display whose results are output. Only active time
domain results can be selected.
Parameters:
<WindowName>
Example:
Manual operation:
User Manual 1173.9240.02 ─ 23
Remote Commands for Analog Demodulation Measurements
.
Window
ON | OFF | 1 | 0
*RST:
0
DIAG:SERV:NSO ON
See
"Noise Source Control"
ON | OFF | 1 | 0
*RST:
0
OUTP:ADEM ON
See
"Online Demodulation Output State"
<string>
String containing the name of the window.
By default, the name of a window is the same as its index. To
determine the name and index of all active windows, use the
LAYout:CATalog[:WINDow]?
FOCus
Dynamically switches to the currently selected window. If a win-
dow is selected that does not contain a time-domain result dis-
play, the selection is ignored and the previous setting is main-
tained.
OUTP:ADEM:ONL:SOUR 'AnalogDemod'
OR:
DISP:WIND1:SEL
OUTP:ADEM:SOUR FOC
See
"Output Selection"
Configuring the Measurement
on page 127
on page 128
query.