A reference value 0 would provide infinite results and is thus automatically corrected to
0.1.
Suffix:
<det>
Parameters:
<RefValue>
Example:
Manual operation:
CONFigure:ADEMod:RESults:AM:DETector<det>:STATe <State>
CONFigure:ADEMod:RESults:FM:DETector<det>:STATe <State>
CONFigure:ADEMod:RESults:PM:DETector<det>:STATe <State>
Activates relative demodulation for the selected detector. If activated, the demodulated
result is set in relation to the reference value defined by
RESults:AM:DETector<det>:REFerence.
Suffix:
<det>
Parameters:
<State>
Example:
Manual operation:
User Manual 1173.9240.02 ─ 23
Remote Commands for Analog Demodulation Measurements
.
1: Positive peak; 2: Negative peak; 3: Average of positive and
negative peaks (+/-PK/2); 4: RMS
Detector function used for relative demodulation
double value
The unit depends on the demodulation type:
AM: %
FM: Hz
PM: depends on
UNIT<n>:ANGLe
*RST:
1.0
See
CONFigure:ADEMod:RESults:PM:DETector<det>:
on page 281
STATe
See
"Reference Value"
.
1: Positive peak; 2: Negative peak; 3: Average of positive and
negative peaks (+/-PK/2); 4: RMS
Detector function used for relative demodulation
ON | OFF | 1 | 0
*RST:
0
CONF:ADEM:RES:PM:DET2:STAT ON
Activates relative demodulation for the negative peak detector.
CONF:ADEM:RES:UNIT PCT
Defines the unit for relative values as percent.
CONF:ADEM:RES:PM:DET2:REF 1.415%
Sets the reference value for the negative peak detector to
1.415 %.
CONF:ADEM:RES:PM:DET2:MODE AVER
Sets the negative peak detector to average mode.
CONF:ADEM:RES:PM:DET2:REF:MEAS
Sets the reference value for the negative peak detector to the
average of the currently calculated value and the previous refer-
ence value.