Manual operation:
CALCulate<n>:DELTamarker<m>:MINimum:NEXT
This command moves a marker to the next higher minimum value.
Suffix:
<n>
<m>
Usage:
Manual operation:
CALCulate<n>:DELTamarker<m>:MINimum[:PEAK]
This command moves a delta marker to the minimum level.
If the marker is not yet active, the command first activates the marker.
Suffix:
<n>
<m>
Usage:
Manual operation:
CALCulate<n>:DELTamarker<m>:MINimum:RIGHt
This command moves a delta marker to the next higher minimum value.
The search includes only measurement values to the right of the current marker posi-
tion.
Suffix:
<n>
<m>
Usage:
Manual operation:
11.8.1.6