R&S FSW-K7 User Manual page 211

Analog demodulation measurement option
Table of Contents

Advertisement

®
R&S
FSW-K7
Parameters:
<PeakVoltage>
Example:
Manual operation:
INPut:IQ:TYPE <DataType>
This command defines the format of the input signal.
Parameters:
<DataType>
Example:
Manual operation:
CALibration:AIQ:HATiming[:STATe] <State>
Activates a mode with enhanced timing accuracy between analog baseband, RF and
external trigger signals.
For more information see the R&S FSW I/Q Analyzer and I/Q Input User Manual.
User Manual 1173.9240.02 ─ 23
Remote Commands for Analog Demodulation Measurements
0.25 V | 0.5 V | 1 V | 2 V
Peak voltage level at the connector.
For probes, the possible full scale values are adapted according
to the probe's attenuation and maximum allowed power.
*RST:
1V
INP:IQ:FULL 0.5V
See
"Full Scale Level Mode / Value"
IQ | I | Q
IQ
The input signal is filtered and resampled to the sample rate of
the application.
Two input channels are required for each input signal, one for
the in-phase component, and one for the quadrature compo-
nent.
I
The in-phase component of the input signal is filtered and
resampled to the sample rate of the application. If the center fre-
quency is not 0, the in-phase component of the input signal is
down-converted first (Low IF I).
Q
The quadrature component of the input signal is filtered and
resampled to the sample rate of the application. If the center fre-
quency is not 0, the quadrature component of the input signal is
down-converted first (Low IF Q).
*RST:
IQ
INP:IQ:TYPE Q
See
"I/Q Mode"
on page 68
Configuring the Measurement
on page 94
211