Accessing the Bandwidth Extension dialog 1 Welcome to the Bandwidth Extension option The R&S SMW-K555 option Bandwidth Extension is a firmware application that allows extension of the modulation bandwidth to up to 4 GHz. This user manual contains a description of the functionality that the application pro- vides, including remote control operation.
® Welcome to the Bandwidth Extension option R&S SMW-K555 Documentation overview 1.3 Documentation overview This section provides an overview of the R&S SMW user documentation. Unless speci- fied otherwise, you find the documents on the R&S SMW product page at: www.rohde-schwarz.com/manual/smw200a...
® Welcome to the Bandwidth Extension option R&S SMW-K555 Documentation overview 1.3.5 Instrument security procedures Deals with security issues when working with the R&S SMW in secure areas. It is avail- able for download on the Internet. 1.3.6 Printed safety instructions Provides safety information in many languages.
® Welcome to the Bandwidth Extension option R&S SMW-K555 Notes on screenshots 1.4 Scope Tasks (in manual or remote operation) that are also performed in the base unit in the same way are not described here. In particular, it includes: ●...
For more information, see data sheet. 2.2 About Bandwidth Extension Equipped with option R&S SMW-K555, the R&S SMW allows you to extend band- widths of I/Q modulated signals. A practical approach is to superimpose RF signals with center frequencies close to each other. The bandwidths of the modulated base- band signal overlap.
Page 10
® About the Bandwidth Extension option R&S SMW-K555 About Bandwidth Extension Figure 2-1: Bandwidth extension without phase corrections = Band A = Band B = Bandwidth band A BW A = Bandwidth band B BW B = Extended bandwidth of band A and band B...
Page 11
® About the Bandwidth Extension option R&S SMW-K555 About Bandwidth Extension band signal source that is the R&S SMW. For test setups, see Chapter 3.1, "Test set- ups", on page 12. User Manual 1179.5776.02 ─ 01...
® Extending the bandwidth R&S SMW-K555 Test setups 3 Extending the bandwidth This chapter provides an overview on how to prepare, configure and operate the R&S SMW for generation of extended bandwidth signals. It covers the following topics: ● Test setups......................12...
® Extending the bandwidth R&S SMW-K555 Test setups www.rohde-schwarz.com/product/fsw The following test setups are described: ● Single R&S SMW with sensor.................13 ● Single R&S SMW with signal analyzer..............13 3.1.1 Single R&S SMW with sensor This test setup includes a single R&S SMW, a power combiner, a directional coupler, a power sensor and the device under test (DUT).
® Extending the bandwidth R&S SMW-K555 Connecting the R&S SMW BW 1 = Bandwidth of the path A output signal BW 2 = Bandwidth of the path B output signal Σ BW = Extended bandwidth signal after combining path A and path B output signals...
Page 15
® Extending the bandwidth R&S SMW-K555 Connecting the R&S SMW c) Connect the RF cables. See chapter "Connecting to RF" in the R&S SMW Getting Started. d) First, start connecting the cable ends with the power combiner. e) Connect both the cable ends with the RF output connectors of the R&S SMW.
Page 16
® Extending the bandwidth R&S SMW-K555 Connecting the R&S SMW For prerequisites of the directional coupler, see "Directional coupler" on page 12. ► Establish the RF connections to the directional coupler as described in the other step-by-step instructions: ● Direction from the power combiner: "To connect a power combiner"...
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW To connect a signal analyzer The following procedure describes how to connect R&S SMW and a directional coupler to an Rohde & Schwarz signal analyzer as alignment source. The R&S SMW and sig- nal analyzer are switched on and connected to power.
Page 18
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW The following steps use the file test_4GHz.bwsa. This file provides a configura- tion for a 4 GHz bandwidth extension setup including a single R&S SMW and a power combiner. 3. Optionally, preview bandwidth extension setup characteristics in the pane to the right of the file list.
Page 19
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW 1 = Bandwidth extension state 2 = Bandwidth extension setup file 3 = Alignment info, alignment status and access to setup alignment wizard 4 = Device under test (DUT) 5 = Power combiner...
Page 20
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW 4. Optionally, configure RF ports. "To monitor the RF ports settings of a single R&S SMW" on page 22. 5. Optionally, configure settings for setup alignment. "To align RF ports with a power sensor"...
Page 21
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW The hostname of the signal analyzer is added automatically. 6. To add the signal analyzer manually, proceed as follows: a) Select "Instrument" > "New". b) Specify hostname or IP address of the signal analyzer.
Page 22
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW 9. Wait until the alignment procedure finishes. Setup alignment can take several minutes. If the alignment finishes, the wizard closes and the setup info button displays no conflict anymore. After setup alignment check, if the RF ports configuration is correct, see "To moni-...
Page 23
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW To align RF ports with a power sensor The power sensor is connected to the R&S SMW, see "To connect an R&S NRP power sensor" on page 16. 1. Edit a bandwidth extension setup file.
Page 24
® Extending the bandwidth R&S SMW-K555 Configuring the R&S SMW If you change parameters of the RF output signal at the R&S SMW, the RF ports are not aligned anymore. For example, if you change the frequency or the level of the RF output signal.
® Extending the bandwidth R&S SMW-K555 Generating signals with extended bandwidth The alignment procedure applies corrections to the local oscillator (LO) phase. If the alignment runs correctly, the "Bw Ext" softkey displays no errors. If you change parameters of the RF output signal at the R&S SMW, the RF ports are not aligned anymore.
Page 26
® Extending the bandwidth R&S SMW-K555 Generating signals with extended bandwidth Figure 3-4: Active bandwidth extension and R&S SMW block diagram 1 = One baseband block for both signal paths "A" and "B" 2 = Configurable settings for signal path A 3 = Configurable output "RF A"...
Page 27
® Extending the bandwidth R&S SMW-K555 Generating signals with extended bandwidth The "Clock Frequency" reads out the ARB clock rate automatically from the wave- form file. You can load waveforms with up to 4.8 GHz clock frequency. 3. Optionally, to monitor further properties of the waveform file, select "Waveform Info".
® Bandwidth Extension settings R&S SMW-K555 General settings 4 Bandwidth Extension settings Access: ► Select "System Configuration" > "Multi Instrument" > Bandwidth Extension". The dialog provides settings to configure settings of the bandwidth extension setup and setup alignment. The remote commands required to define these settings are described in Chapter 5, "Remote control...
Page 29
® Bandwidth Extension settings R&S SMW-K555 General settings The "Bandwidth Extension" side-tab provides general settings to configure settings of the bandwidth extension setup. Also it provides access to settings for setup alignment. Settings: State..........................29 Setup..........................29 Info / Align........................29 Setup info........................
Page 30
® Bandwidth Extension settings R&S SMW-K555 General settings 1 = Bandwidth extension state 2 = Bandwidth extension setup file 3 = Alignment info, alignment status and access to setup alignment wizard 4 = Device under test (DUT) 5 = Power combiner 6 = Signal generator block Signal generator block ←...
® Bandwidth Extension settings R&S SMW-K555 Setup file editor settings The dialog provides common settings to save the configuration of the bandwidth extension setup in a file. Settings: Save Setup........................32 Save Setup as.......................32 Save Setup Saves the current configuration of the bandwidth extension setup file.
Page 33
® Bandwidth Extension settings R&S SMW-K555 Setup file editor settings Settings: Number of Ports......................33 Resulting Bandwidth..................... 33 Maximum Center Frequency..................33 Scan Instrument......................33 RF port table......................... 33 └ Port Name.......................33 └ Source.......................33 └ Hostname / IP Address................... 33 └...
® Bandwidth Extension settings R&S SMW-K555 Setup file editor settings Remote Status ← RF port table Indicates the remote connection status. The RF port belongs to a secondary instrument; the remote connec- tion to the secondary instrument can be established.
Page 35
® Bandwidth Extension settings R&S SMW-K555 Setup file editor settings └ Scan Analyzers....................35 └ Instrument....................... 35 └ Hostname or IP Address.................36 Coupler........................36 Measurement Device Selects the measurement device. This device is the source instrument for RF ports alignment.
® Bandwidth Extension settings R&S SMW-K555 Setup info and alignment settings Hostname or IP Address ← Analyzer settings Displays or sets the hostname or IP address of the vector signal analyzer. Remote command: n.a. Use Coupler Optimizes RF ports alignment by coupling with a directional coupler.
Page 37
® Bandwidth Extension settings R&S SMW-K555 Setup info and alignment settings Align Date / Time Displays the date and time of the last alignment procedure. Remote command: on page 41 :SCONfiguration:BEXTension:STATe Align Setup Accesses the "Align Setup" wizard. Alignment Parameters Displays all relevant parameters for alignment.
Page 39
® Bandwidth Extension settings R&S SMW-K555 Align setup wizard settings Alignment Parameters Sets all relevant parameters for alignment. Start RF Frequency ← Alignment Parameters Sets/displays the start frequency of the aligment procedure. Make sure, that the measurement device supports this start frequency.
® Remote control commands R&S SMW-K555 5 Remote control commands The following commands are required to generate signals with the Bandwidth Exten- sion option in a remote environment. We assume that the R&S SMW has already been set up for remote operation in a network as described in the R&S SMW documentation.
® Remote control commands R&S SMW-K555 General commands The following chapters describe the commands specific to the Bandwidth Extension option. ● General commands....................41 ● Alignment commands....................42 5.1 General commands The SCONfiguration:BEXTension subsystem contains the commands for configu- ration of a bandwidth extension setup.
® Remote control commands R&S SMW-K555 Alignment commands Manual operation: "State" on page 29 "Align Date / Time" on page 37 5.2 Alignment commands The SCONfiguration:BEXTension:ALIGn subsystem contains the commands for aligning a bandwidth extension setup. Example: Aligning the bandwidth extension setup and RF ports SCONfiguration:BEXTension:ALIGn:STATus? // Repsonse: "NALigned"...
Page 43
® Remote control commands R&S SMW-K555 Alignment commands Usage: Query only Manual operation: "Info / Align" on page 29 User Manual 1179.5776.02 ─ 01...
® List of commands R&S SMW-K555 List of commands :SCONfiguration:BEXTension:ALIGn:RFPorts....................42 :SCONfiguration:BEXTension:ALIGn:STATus?....................42 :SCONfiguration:BEXTension:SETup:FILE......................41 :SCONfiguration:BEXTension:STATe.......................41 User Manual 1179.5776.02 ─ 01...