R&S FSW-K7 User Manual page 273

Analog demodulation measurement option
Table of Contents

Advertisement

®
R&S
FSW-K7
Specific commands:
[SENSe:]ADEMod<n>:SPECtrum:SPAN:ZOOM
[SENSe:]ADEMod<n>:SPECtrum:SPAN[:MAXimum]
[SENSe:]ADEMod<n>:SPECtrum:SPAN:ZOOM <Span>
This command sets the span (around the center frequency) for RF spectrum result dis-
play.
The span is limited to the demodulation bandwidth (see
on page 254).
Suffix:
<n>
Parameters:
<Span>
Example:
Manual operation:
[SENSe:]ADEMod<n>:SPECtrum:SPAN[:MAXimum] <FreqRange>
Sets the DBW to the specified value and the span (around the center frequency) of the
RF data to be evaluated to its new maximum (the demodulation bandwidth).
Suffix:
<n>
Parameters:
<FreqRange>
Manual operation:
11.4.8.4
(Post-processing) AF Filters
The AF filter reduces the evaluated bandwidth of the demodulated signal and can
define a weighting function. AF filters are only available for AM or FM time domain
evaluations.
[SENSe:]FILTer<n>:AWEighted[:STATe]
[SENSe:]FILTer<n>:AOFF
[SENSe:]FILTer<n>:CCIR:WEIGhted[:STATe]
[SENSe:]FILTer<n>:CCIR:[:UNWeighted][:STATe]
[SENSe:]FILTer<n>:CCITt
[SENSe:]FILTer<n>:DEMPhasis:TCONstant
[SENSe:]FILTer<n>:DEMPhasis[:STATe]
[SENSe:]FILTer<n>:HPASs:FREQuency[:ABSolute]
[SENSe:]FILTer<n>:HPASs:FREQuency:MANual
User Manual 1173.9240.02 ─ 23
Remote Commands for Analog Demodulation Measurements
................................................................273
.
irrelevant
*RST:
5 MHz
ADEM:SPEC:SPAN:ZOOM 200 kHz
Sets the rF span to 200 kHz
See
"Span"
on page 115
.
irrelevant
*RST:
5 MHz
Default unit: Hz
See
"Span"
on page 115
See
"RF Full Span"
on page 116
.......................................................................... 274
.............................................................................................. 274
.................................................................. 274
.............................................................................................. 275
.....................................................................275
......................................................................... 276
Configuring the Measurement
.........................................................273
[SENSe:]BWIDth:DEMod
............................................................ 275
..........................................................276
............................................................. 276
273

Advertisement

Table of Contents
loading

Table of Contents