R&S FSW-K7 User Manual page 165

Analog demodulation measurement option
Table of Contents

Advertisement

®
R&S
FSW-K7
7. In the file selection dialog box, select a storage location and enter a file name.
8. Select "Save".
The captured data is stored to a file with the extension .iq.tar.
Importing I/Q data
1. Press the MODE key and select the "I/Q Analyzer" or any other application that
supports I/Q data.
2. If necessary, switch to single sweep mode by pressing the RUN SINGLE key.
3. Select the
4. Select the "I/Q Import" softkey.
5. Select the storage location and the file name with the .iq.tar file extension.
6. Select "Open".
The stored data is loaded from the file and displayed in the current application.
Previewing the I/Q data in a web browser
The iq-tar file format allows you to preview the I/Q data in a web browser.
1. Use an archive tool (e.g. WinZip® or PowerArchiver®) to unpack the iq-tar file
into a folder.
2. Locate the folder using Windows Explorer.
3. Open your web browser.
User Manual 1173.9240.02 ─ 23
"Open" icon in the toolbar.
I/Q Data Import and Export
How to Export and Import I/Q Data