+100 to +199 Core Device-Specific Error
Description
A device-specific error indicates that the instrument has detected an error that occurred because some
operations did not properly complete, possibly due to an abnormal hardware or firmware condition. For
example, an attempt by the user to set an out of range value will generate a device specific error.
These are general errors generated by the core instrument. When one of these errors is generated, the '+100
errors' bit in the questionable error status register is set.
Error Message
+101 Assert; Cycle power. Assert message<message1>
+102 Exception; Cycle power. Exception
message<message2>
+103 Failure; No measurements or settings can be made
+104 Failure; No settling operations will take place
+105 Failure; No measurements or setting can be made
for the function selected
+110 Input pacing; Internal communication queue
overflow likely
+111 Input pacing; Internal communication queue
overflow imminent. Pacing increased
+112 Internal error; Protocol error <message3>
Description
<message1> will appear as:
If the DSP generated the assert:
;P:DSP T:<task ID> E:<error code> C:<error
classif.> F1:<flag 1> F2:<flag 2>
If the Protocol processor generated the assert:
;P:Protocol T:<task ID> L:<line number> F:<file
name>
If the Host processor generated the assert:
;P:Host T:<task ID> L:<line number> F:<file
name>
<message2> will appear as: T:<task ID> or V:<vector
number> or PC:<program counter> or DA:<data adrs
reg value>.
Vector number, program counter and data address
register values are hexadecimal format.
Indicates none of the VI's are operational because a
serious problem exists.
Indicates none of the VI's are operational because a
serious problem exists.
Indicates none of the VI's are operational because a
serious problem exists.
Indicates that GPIB commands are too fast for the
device input queue and should be slowed.
Indicates that GPIB commands were too fast and the
device input queue has not kept pace.
<message3> is an eight digit hexadecimal number that
is the error code reported by protocol.
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\ts_err_msg_pos100.fm
+100 to +199 Core Device-Specific Error