SETup:BERRor:CLSDelay:STATe
Function
Selects/queries the closed loop signalling delay state for Bit Error measurements. If the state is
off the test set will not wait to start a BERR measurement after a downlink signalling operation
has completed.
The delay time defines how long the test set should wait before starting and BERR measurement
after a downlink signalling operation has completed and after the test set has sent a close loop
command to the MS.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the
BERR measurement from starting for the specified time period.
Setting
Range: 1 | ON | 0 | OFF
Query
Range: 1 | 0
*RST
1 | ON
Programming Example
OUTPUT 714;"SETUP:BERROR:CLSDELAY:STATE ON"
SETup:BERRor[:TYPE]
Function
Sets the measurement type for BER measurements including Type A (residual) and Type B
(non-residual).
Setting
Range:
TYPEIA | TYPEII |TYPEIB | RESTYPEIA | RESTYPEII | RESTYPEIB
Query
Range:
TYPEIA | TYPEII |TYPEIB | RESTYPEIA | RESTYPEII | RESTYPEIB
*RST Setting
RESTYPEII
Programming Example
OUTPUT 714;"SETUP:BERROR:TYPE TYPEIA" !Sets type of BER measurement.
SETup:BERRor:CONTinuous
Function
Sets/queries the trigger state to single trigger mode or continuous trigger mode for BER
measurement.
Setting
Range: 0|OFF | 1|ON
Query
0|1
*RST Setting
0|off
Programming Example
OUTPUT 714;"BERROR:CONTINUOUS OFF" !Sets BER measurement to single trigger mode.
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_setup_berror.fm
SETup:BERRor
387

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5515aE5515bE1960a

Table of Contents