Agilent Technologies 8960 10 Series Reference Manual page 392

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

SETup:FBERror
SETup:FBERror:CLSDelay[:STIMe]
Function
Selects/queries the closed loop signalling delay time in seconds for Fast Bit Error measurements
and sets the delay state to ON. The units (S|MS) are optional, if no units are specified than units
default to S.
The delay time defines how long the test set should wait before starting a FBER measurement.
The downlink signalling operation must be completed and the test set must send a close loop
command to the MS before the measurement can begin. The delay time allows time for the loop to
close.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the
FBER measurement from starting for the specified time period.
Setting
Range: 0 to 5 seconds
Resolution: 100 ms
Query
Range: 0 to 5 seconds
Resolution: 100 ms
*RST
500 ms
Programming Example
OUTPUT 714;"SETUP:FBERROR:CLSDELAY:STIME 500 MS" ! Sets the Close Loop Delay
SETup:FBERror:CLSDelay:TIME
Function
Selects/queries the closed loop signalling delay time in seconds for Fast Bit Error measurements.
The units (S|MS) are optional, if no units are specified than units default to S.
The delay time defines how long the test set should wait before starting a FBER measurement.
The downlink signalling operation must be completed and the test set must send a close loop
command to the MS before the measurement can begin. The delay time allows time for the loop to
close.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the
FBER measurement from starting for the specified time period.
Setting
Range: 0 to 5 seconds
Resolution: 100 ms
Query
Range: 0 to 5 seconds
Resolution: 100ms
*RST
500 ms
Programming Example
OUTPUT 714;"SETUP:FBERROR:CLSDELAY:TIME 500 MS" ! Sets the Close Loop Delay