DISPlay
DISPlay
:BRIGhtness
:MODE
:MESSage
:WINDow
"Diagram Conventions" on page 213
DISPlay:BRIGhtness
Function
Sets/queries the test set's display brightness.
A display backlight dimming feature lowers the display brightness after approximately 10
minutes without any manual user interaction with the test set. See
on page
Setting
Range: MEDium | HIGH
Query
Range: MED | HIGH
Factory
HIGH (this parameter is not affected by any reset operation and can only be changed by direct
setting
user access)
Programming Example
OUTPUT 714;"DISPLAY:BRIGHTNESS MEDIUM" !Sets display brightness to medium.
<sp>HIGH|MEDium
?
<sp>FAST|TRACk
?
:MASKable
:ERRor
292.
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_display.fm
:STATe
<sp>1|ON|0|OFF
? (returns 1|0)
:CLEar