SETup:TXPower
SETup:TXPower:TRIGger:QUALifier
Function
Sets/queries the trigger qualification for TX carrier power measurements. When ON, an
automatic trigger re-arm occurs if a measurement is triggered when no valid signal (burst) is
present. See
Setting
0|OFF | 1|ON
Query
0|1
*RST Setting
1|on
Programming Example
OUTPUT 714;"SETUP:TXPOWER:TRIGGER:QUALIFIER ON" !Sets trigger qualifier state
436
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_setup_txpower.fm
"Trigger Qualifier Description" on page 152
!to on.