Example 8. BCH Test Function Using Auto Receiver Control
The following example shows how to set up a test mode measurement using the BCH test function. In this
example the test set is configured to transmit a BCH on PGSM channel 21, and receive the mobile station on
PGSM channel 21 at a power level of 12.
1. Select test mode.
OUTPUT 714;"CALL:OPERATING:MODE TEST"
2. Select PGSM as the broadcast band.
OUTPUT 714;"CALL:CELL:BAND PGSM"
3. Select BCH as the test function.
OUTPUT 714;"CALL:FUNCTION:DOWNLINK BCH"
4. Configure the receiver control to auto.
OUTPUT 714;"RFANALYZER:CONTROL:AUTO ON"
5. Set the BCH to channel 21.
OUTPUT 714;"CALL:BCH:PGSM 21"
6. Set the MS TX level to 12.
OUTPUT 714;"CALL:MS:TXLEVEL 12"
7. To make the measurement, set up the mobile station to transmit on PGSM channel 21 at a power level of
12.
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\gen_bse_test.fm
Test Mode Operating Mode
527