CALL:MS
CALL:MS:DTX[:STATe]
Function
Turns mobile station Discontinuous Transmission (DTX) on or off. Query form returns a 1 (state
= on) or a 0 (state = off). See
Setting
range: 1 | ON | 0 | OFF
Query
range: 0 | 1
*RST Setting
0 (state = OFF)
Programming Example
OUTPUT 714;"CALL:MS:DTX OFF" !Turns mobile station discontinuous
CALL:MS:REPorted:CLEar
Function
Clears the mobile station SAACH reported items. The values of the four mobile reported items -
that is, Timing Adv, Tx Level, Rx Level and Rx Qual - are set to 9.91E+37 (NAN).
Programming Example
OUTPUT 714;"CALL:MS:REPORTED:CLEAR"
CALL:MS:REPorted:IMEI?
Function
Query of the International Mobile Equipment Identity of the ME. ME is an MS without a SIM.
This parameter is reported if the IMEI:AUTO state is ON, see
MS has no SIM.
Query
range: up to 15 decimal digits and ""
resolution: 1
*RST Setting
"" (null string)
Programming Example
OUTPUT 714;"CALL:MS:REPORTED:IMEI?"
CALL:MS:REPorted:IMSI?
Function
Query of the International Mobile Subscriber Identity of the SIM in the MS.
Query
range: up to 15 decimal digits and ""
resolution: 1
*RST Setting
"" (null string)
Programming Example
OUTPUT 714;"CALL:MS:REPORTED:IMSI?"
256
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_call_ms.fm
"Configuring Mobile Station Operating Parameters" on page
!transmission OFF.
"CALL:IMEI" on page 250
517.
or the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5515aE5515bE1960a

Table of Contents