CALL:COUNt
CALL:COUNt:CLEAr:BAERror
Function
Sets the corrupt burst, missing burst, and decode error counters' count to zero.
Programming Example
OUTPUT 714;"CALL:COUNT:CLEAR:BAERROR"
CALL:COUNt:CLEAr:RAPage
Function
Sets the RACH and page counters' count to zero.
Programming Example
OUTPUT 714;"CALL:COUNT:CLEAR:RAPAGE"
CALL:COUNt:MBURst?
Function
Queries the missing burst counter. The missing burst counter keeps track of how many
uplink bursts, that should have been there, were missing. The missing burst counter does not
count idle frames as missing.
Query
Range: 0 to 99999
Resolution: 1
*RST Setting
0
Programming Example
OUTPUT 714;"CALL:COUNT:MBURST?"
CALL:COUNt:PAGE?
Function
Queries the page counter. The page counter keeps track of the number of pages sent by the
base station (BS) emulator during a BS originated call setup.
Query
Range: 0 to 9999
Resolution: 1
*RST Setting
0
Programming Example
OUTPUT 714;"CALL:COUNT:PAGE?"