SETup:IQTuning:TRIGger:DELay
Function
Sets/queries the trigger delay time in seconds for an I/Q Tuning measurement. The units
(S|MS|US|NS) are optional, if no units are specified then the default is S.
Setting
Range: -2.31 ms to +2.31 ms
Resolution: 5 significant digits or 100 ns, whichever is greater
Query
Range: -2.31 ms to +2.31 ms
Resolution: 5 significant digits or 100 ns, whichever is greater
*RST
zero seconds
Programming Example
OUTPUT 714;"SETUP:IQTUNING:TRIGGER:DELAY 1.2MS" !Sets the trigger delay
time to 1.2 milli seconds.
XXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
SETup:IQTuning:TRIGger:SOURce
Function
Sets/queries the trigger source for an I/Q Tuning measurement.
Setting
RISE|IMMediate
See
"Triggering of Measurements" on page
Query
RISE|IMM
*RST
RISE
Programming Example
OUTPUT 714;"SETUP:IQTUNING:TRIGGER:SOURCE IMM" !Sets the trigger source to
immediate.