Agilent Technologies 8960 10 Series Reference Manual page 231

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

CALL[:CELL]:BA:TABLe:PCS
Function
Sets/queries the BA Table entries for the PCS broadcast band. Entries are set (value entered into
table and state set to ON) using a comma separated list of 1 to 16 values. States of table entries
not included in setting list are set to OFF. Sending a null list (no values) sets states of all table
entries to OFF. Query returns a comma separated list of the table entries that are in the ON
state. If states of all table entries are set to OFF, query returns NAN (9.91E+37).
Setting
range: 512 to 810
resolution: 1
Query
range: 0 to 9.91E+37
*RST Setting
entries: 512, 660, 810, 530, 550, 570, 590, 610, 630, 650, 690, 710, 730, 750, 770, 790
states:
Programming Example
OUTPUT 714;"CALL:CELL:BA:TABLE:PCS 660,710,790" !Sets three BA table entries for
OUTPUT 714;"CALL:CELL:BA:TABLE:PCS" !Sets states of all table entries to OFF.
CALL[:CELL]:BA:TABLe:PGSM
Function
Sets/queries the BA Table entries for the PGSM broadcast band. Entries are set (value entered
into table and state set to ON) using a comma separated list of 1 to 16 values. States of table
entries not included in setting list are set to OFF. Sending a null list (no values) sets states of all
table entries to OFF. Query returns a comma separated list of the table entries that are in the
ON state. If states of all table entries are set to OFF, query returns NAN (9.91E+37).
Setting
range: 1 to 124
resolution: 1
Query
range: 0 to 9.91E+37
*RST Setting
entries: 20, 1, 62, 124, 9, 18, 36, 45, 54, 63, 72, 81, 90, 99, 108, 117
states:
Programming Example
OUTPUT 714;"CALL:CELL:BA:TABLE:PGSM 20,36,120" !Sets three BA Table entries for
OUTPUT 714;"CALL:CELL:BA:TABLE:PGSM" !Sets states of all BA Table entries to OFF.
512 = ON, all others = OFF
20 = ON, all others = OFF
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_call_ba.fm
!the PCS broadcast band. States
!of the remaining 13 entries are
!set to OFF.
!the PGSM broadcast band. States
!of the remaining 13 entries are
!set to OFF.
CALL:BA