Agilent Technologies 8960 10 Series Reference Manual page 577

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

Error Messages
Maskable Message Display State The Maskable Messages Display State found in the Instrument Setup menu gives
users a way to block these messages and the associated beep from ever happening. When the state is Off these messages
and their associated beep will be blocked. The Maskable Message Display State can be set manually or with the following
GPIB command:
OUTPUT 714;"DISPLAY:MESSAGE:MASKABLE:STATE OFF" !Prevents certain messages from appearing on the
display.
Instrument Maskable Messages
• Instrument warning: Audio Generator instrument has been closed.
• Instrument warning: Audio Analyzer instrument has been closed.
• Instrument warning: Analog Audio instrument has been closed.
GSM Mobile Test Maskable Messages
• GSM measurement warning; TX Power measurement has been closed.
• GSM measurement warning; Power vs Time measurement has been closed.
• GSM measurement warning; Phase Frequency Error measurement has been closed.
• GSM measurement warning; Output RF Spectrum measurement has been closed.
• GSM measurement warning; Fast Bit Error measurement has been closed.
• GSM measurement warning; Decoded Audio measurement has been closed.
• GSM measurement warning; IQ Tuning measurement has been closed.
Related Topics
*******************************************************
"SYSTem:COMMunicate:GPIB:DEBug[:STATe]" on page 482
"Test Set Beeper" on page 556
"SYSTem:ERRor?" on page 488
"DISPlay:WINDow:ERRor:CLEar"
"DISPlay:MESSage:MASKable:STATe" on page 294
"Integrity Indicator" on page 125
"FETCh? Subsystem" on page 295
*******************************************************
577
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\ts_err_msg.fm