Agilent Technologies 8960 10 Series Reference Manual page 390

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

SETup:BERRor
SETup:BERRor:TIMeout[:STIMe]
Function
Sets/queries the timeout value in seconds for the trigger state during BER measurements and
turns the timeout state on. The units (S|MS) are optional, if no units are specified than units
default to S.
Setting
Range: .1 to 999
Resolution: .1
Query
Range: .1 to 999
Resolution: .1
*RST Setting
10 seconds
Programming Example
OUTPUT 714;"SETUP:BERR:TIMEOUT:STIME 8" !Sets BER measurement timeout to
SETup:BERRor:TIMeout:TIME
Function
Sets/queries the timeout value in seconds for the trigger state during BER measurements. The
units (S|MS) are optional, if no units are specified than units default to S (seconds).
Setting
Range: .1 to 999
Resolution: .1
Query
Range: .1 to 999
Resolution: .1
*RST Setting
10 seconds
Programming Example
OUTPUT 714;"SETUP:BERR:TIMEOUT:TIME 8" !Sets BER measurement timeout to
SETup:BERRor:TIMeout:STATe
Function
Sets/queries the timeout state for BER measurements.
Setting
Range: 0 | OFF | 1 | ON
Query
0 | 1
*RST Setting
0 | off
Programming Example
OUTPUT 714;"SETUP:BERR0R:TIMEOUT:STATE ON" !Sets the timeout state to on.
390
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_setup_berror.fm
!8 seconds and the state to on.