STATus:OPERation:CALL:COMMon Condition Register Bit Assignment
The STATus:OPERation:CALL:AMPS:COMMon register bits will be used to indicate status of processes that
occur during normal call processing operations.
Bit
Binary
Number
Weighting
15
32768
14
16384
13
8192
12
4096
11
2048
10
1024
9
512
8
256
7
128
6
64
5
32
4
16
3
8
2
4
1
2
0
1
Condition
Not Used. Defined by SCPI.
Reserved for future use.
Reserved for future use.)
Reserved for future use.
Reserved for future use.
Registering (MS initiated)
Registering (BS initiated)
Reserved for future use.
BS Originating
Call Control Status Changing
Reserved for future use.
Reserved for future use.
Call Control Status Alerting
Call Control Status Connected
Call Control Status Idle
Extension Bit
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_status_operation.fm
Description
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
This bit is set to a 1 when the Mobile Station
initiates registration.
This bit is set to a 1 when the Base Station initiates
registration.
This bit will always be 0.
This bit will be a 1 when:
• Active Cell mode - the call processing state
leaves the idle state
• Test mode - the test set has noted a base station
origination.
This bit is set to a 1 when the call control status
change detector has been armed.
This bit will always be 0.
This bit will always be 0.
This bit will be a 1 when the test set is in the call
alerting state (ringing).
This bit will be a 1 when the test set is in the call
connected state.
This bit will be a 1 when the test set is in the call
idle state.
This bit will always be 0.
STATus:OPERation