Agilent Technologies 8960 10 Series Reference Manual page 372

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

RFANalyzer
RFANalyzer:CONTrol:AUTO
Function
Sets/queries the test set's receiver control. The measuring receiver is under the control of the
test set's base station emulator (auto) or under the control of the user (manual). see
Control" on page 518
Setting the manual band will change the receiver control to manual. see
"RFANalyzer:MANual:BAND" on page 375
Setting the manual channel in the band that is currently active will change the receiver control
to manual.
Setting the manual frequency will change the receiver control to manual. see
"RFANalyzer:MANual:FREQuency" on page 378
Setting the broadcast band will change the receiver control to auto. See
234
Setting
Manual = 0|OFF , Auto = 1|ON (default ON)
Query
0|1
*RST setting
0|on
Programming Example
OUTPUT 714;"RFANALYZER:CONTROL:CONTROL:AUTO 0" !Sets receiver control to manual.
RFANalyzer:EXPected:POWer[:SELected]
Function
Sets/queries the power level in DBM that the mobile station is expected to transmit for the
selected band. The units DBM are optional. The test set will set up its input signal path to
measure this power level when a user is in manual control. See
Setting
Range: -60 to +53 dBm, after the Amplitude Offset (optional) has been factored in. see
"Measurement Related Configuration" on page 563
Resolution: .01 DBM
Query
Range: -60 to +53 dBm, after the Amplitude Offset (optional) has been factored in. see
"Measurement Related Configuration" on page 563
Resolution: .01 DBM
*RST setting
Sets the receiver control to auto
Band: PGSM
Expected Power: +13DBM
Programming Example
OUTPUT 714;"RFANALYZER:EXPECTED:POWER:SELECTED 10" !Sets the test set expected
372
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_rfanalyzer.fm
see"RFANalyzer:MANual:CHANnel[:SELected]" on page 375
"CALL:BAND" on page
"Expected Power" on page
!input level to 10 DBM.
"Receiver
520.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5515aE5515bE1960a

Table of Contents