STATus:QUEStionable
STATus:QUEStionable:ERRors:COMMon Condition Register Bit Assignment
The STATus:QUEStionable:ERRors:COMMon register bits will be used to indicate information about test set
device-specific errors (positive error numbers).
Bit
Binary
Number
Weighting
15
32768
14
16384
13
8192
12
4096
11
2048
10
1024
9
512
8
256
7
128
6
64
5
32
4
16
3
8
464
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_STATus_QUEStionable.fm
Condition
Not Used. Defined by SCPI.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
+900 Errors
+800 Errors
+700 Errors
+600 Errors
+500 Errors
+400 Errors
+300 Errors
Description
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
This bit will always be 0.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +900 to
+999 range occurs. Query the Event Register to find
out if one of these errors occurred.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +800 to
+899 range occurs. Query the Event Register to find
out if one of these errors occurred.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +700 to
+799 range occurs. Query the Event Register to find
out if one of these errors occurred.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +600 to
+699 range occurs. Query the Event Register to find
out if one of these errors occurred.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +500 to
+599 range occurs. Query the Event Register to find
out if one of these errors occurred.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +400 to
+499 range occurs. Query the Event Register to find
out if one of these errors occurred.
The condition bit will be pulsed to a 1 and
immediately back to 0 if an error in the +300 to
+399 range occurs. Query the Event Register to find
out if one of these errors occurred.