Overview
Terminating an active call with the mobile station when the test set is in active cell operating mode can be
accomplished in one of two ways:
• Terminate the active call from the base station emulator
• Terminate the active call from the mobile station
Terminating an Active Call from the Base Station Emulator
The recommended process for terminating an active call from the base station emulator is shown in the
following figure.
The CALL:END command is used to initiate a base station disconnect.
Step 8: Figure 1. Process for Terminating an Active Call from the BSE
Start
Send CALL:END
command.
Send call connected
state query
command.
Enter response from
call connected state
query.
Call connected?
No
Proceed with control
program.
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\prog_prog_guide_step8.fm
Step 8: Disconnect the Mobile Station from the BSE
Yes
Invoke error
handler.
197