Call:count - Agilent Technologies 8960 10 Series Reference Manual

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

CALL:COUNt

CALL
:COUNt
"Diagram Conventions" on page 213
CALL:COUNt:CBURst?
Function
Queries the corrupt burst counter. The corrupt burst counter keeps track of the number of uplink
bursts where power was detected but the expected midamble could not be found.
Query
Range: 0 to 99999
Resolution: 1
*RST Setting
0
Programming Example
OUTPUT 714;"CALL:COUNT:CBURST?" !Queries the corrupt burst counter.
CALL:COUNt:CDERror?
Function
Queries the channel decode error counter. The channel decode error counter keeps track of how
many channel decoder errors have occurred. Channel decode errors include convolutional, FIRE,
and block errors, but not CRC errors.
Query
Range: 0 to 99999
Resolution: 1
*RST Setting
0
Programming Example
OUTPUT 714;"CALL:COUNT:CDERROR?" !Queries the channel decode error counter.
:CBURst?
:CDERror?
:CLEar
:BAERror
:RAPage
:MBURst?
:PAGE?
:RACH?
:TDMA:FRAMes