Log configuration using the ACLI
Prerequisites
• Access Global Configuration mode.
Procedure steps
1. To begin logging system messages on the PCMCIA (or external flash) card, use
2. To stop logging:
Configuring system message control
Configure system message control to suppress duplicate error messages on the console, and
to determine the action to take if they occur.
Prerequisites
• Access Global Configuration mode.
Procedure steps
1. Configure system message control action by using the following command:
2. Configure the maximum number of messages by using the following command:
3. Configure the interval by using the following command:
4. Enable message control:
330
Troubleshooting
the following command:
log logToPCMCIA
no log logToPCMCIA
sys msg-control action <suppress-msg|send-trap|both>
sys msg-control max-msg-num <2-500>
sys msg-control control-interval control-interval <1-30>
sys msg-control
Comments? infodev@avaya.com
July 2013