Configuring Target Table Parameters - Avaya 8800 Troubleshooting Manual

Ethernet routing switch
Table of Contents

Advertisement

MMS

Configuring target table parameters

Configure the target table to set parameters such as SNMP version and security levels. The
target table contains the security parameters for SNMP.
Procedure steps
1. In the navigation tree, open the following folders: Configuration > Edit >
2. Click Target Table.
3. Click the Target Params Table tab.
4. Click Insert.
5. In the Name box, type a target table name.
6. From the MPModel options, select an SNMP version.
7. From the Security Model options, select the security model.
8. In the SecurityName box, type readview or writeview.
9. From the SecurityLevel options, select the security level for the table.
10. Click Insert.
Variable definitions
Use the information in the following table to configure a target table with SNMP security
parameters.
Name
MPModel
Troubleshooting
Variable
SNMPv3.
Variable
Identifies the target table.
Specifies the Message Processing Model (MPM) to use
to generate messages: SNMPv1, SNMPv2c, or
SNMPv3/USM.
Specifies the maximum message size. The size can be
zero, or 484 to 2147483647. The default is 484.
Although the maximum MMS is 2147483647, the switch
supports the maximum SNMP packet size of 8192.
Configuring target table parameters
Value
Value
July 2013
271

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

8600

Table of Contents