Routine Maintenance

Avaya Ethernet Routing Switch 8800/8600
7.1
NN46205-312, 04.03
March 2011

Advertisement

Table of Contents
loading

Summary of Contents for Avaya 8800

  • Page 1: Routine Maintenance

    Routine Maintenance Avaya Ethernet Routing Switch 8800/8600 NN46205-312, 04.03 March 2011...
  • Page 2 Product provided by Avaya including the selection, arrangement and While reasonable efforts have been made to ensure that the design of the content is owned either by Avaya or its licensors and is information in this document is complete and accurate at the time of protected by copyright and other intellectual property laws including the printing, Avaya assumes no liability for any errors.
  • Page 3: Table Of Contents

    Contents Chapter 1: Regulatory Information and Safety Precautions..........5 Chapter 2: New in this release....................17 Chapter 3: Introduction......................19 Chapter 4: Fan Tray and Cooling Module cleaning..............21 Cleaning fan trays in an 8003-R chassis......................21 Cleaning fans trays or cooling modules in an 8006 or 8010 chassis..............23 Cleaning fans in an 8010co chassis........................29 Chapter 5: Chassis slots and backplane cleaning...............33 Cleaning slots and backplane procedures......................33...
  • Page 4 Electromagnetic interference caution statement...................112 Fan tray warning statement...........................114 Connection cable caution statement......................115 Chapter 13: Customer service....................117 Navigation..............................117 Getting technical documentation........................117 Getting Product training..........................117 Getting help from a distributor or reseller......................117 Getting technical support from the Avaya Web site..................118 Routine Maintenance March 2011...
  • Page 5: Chapter 1: Regulatory Information And Safety Precautions

    Read the information in this section to learn about regulatory conformities and compliances. International Regulatory Statements of Conformity This is to certify that the Avaya 8000 Series chassis and components installed within the chassis were evaluated to the international regulatory standards for electromagnetic...
  • Page 6: Canadian Department Of Communications Radio Interference Regulations

    CE Marking Statement (Europe only) EN 55 022 Statements This is to certify that the Avaya 8800/8600 Series chassis and components installed within the chassis are shielded against the generation of radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
  • Page 7: En 300386 Statement

    Telecommunications centre or locations other than telecommunications centres given the performance criteria as specified by the manufacturer. EC Declaration of Conformity The Ethernet Routing Switch 8800/8600 Series chassis conforms to the provisions of the R&TTE Directive 1999/5/EC. European Union and European Free Trade Association (EFTA) Notice All products labeled with the CE marking comply with R&TTE Directive (1999/5/...
  • Page 8: National Safety Statements Of Compliance

    CE Marking Statement (Europe only) EN 60 950 Statement This is to certify that the Avaya 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive.
  • Page 9 Norma Oficial Mexicana (NOM): Exportador: Avaya Inc 4655 Great America Parkway Santa Clara, CA 95054 USA Importador: AVAYA COMMUNICATION DE MÉXICO SA DE CV Av. Presidente Masarik 111 Piso 6 Col Chapultepec Morales Deleg. Miguel HIdalgo México D.F. 11570...
  • Page 10: Safety Messages

    Denan Statement (Japan/Nippon only) Safety Messages This section describes the different precautionary notices used in this document. This section also contains precautionary notices that you must read for safe operation of the Avaya Ethernet Routing Switch 8800/8600. Notices Notice paragraphs alert you about issues that require your attention. The following sections describe the types of notices.
  • Page 11 Electrostatic alert: PRECAUCIÓN ESD (Descarga electrostática) El aviso de ESD brinda información acerca de cómo evitar una descarga de electricidad estática y el daño posterior a los productos Avaya. Electrostatic alert: CUIDADO ESD Os avisos do ESD oferecem informações sobre como evitar descarga de eletricidade estática e os conseqüentes danos aos produtos da Avaya.
  • Page 12 Schäden an Avaya-Produkten verhindert. Caution: PRECAUCIÓN Los avisos de Precaución brindan información acerca de cómo evitar posibles interrupciones del servicio o el daño a los productos Avaya. Caution: CUIDADO Os avisos de cuidado oferecem informações sobre como evitar possíveis interrupções do serviço ou danos aos produtos da Avaya.
  • Page 13 Notices Warning: AVERTISSEMENT La mention Avertissement fournit des informations sur les moyens de prévenir les risques de blessure lors de la manipulation de produits Avaya. Warning: WARNUNG Warnhinweise bieten Informationen dazu, wie man Personenschäden bei der Arbeit mit Avaya-Produkten verhindert.
  • Page 14 Regulatory Information and Safety Precautions Hinweise mit „Vorsicht – Hochspannung“ bieten Informationen dazu, wie man Situationen oder Umstände verhindert, die zu schweren Personenschäden oder Tod durch Hochspannung oder Stromschlag führen können. Voltage: PELIGRO Los avisos de Peligro-Alto voltaje brindan información acerca de cómo evitar una situación o condición que cause graves lesiones a personas o la muerte, a causa de una electrocución o de una descarga de alto voltaje.
  • Page 15 Notices Los avisos de Peligro brindan información acerca de cómo evitar una situación o condición que pueda causar lesiones personales graves o la muerte. Danger: PERIGO Avisos de perigo oferecem informações sobre como evitar uma situação ou condição que possa causar graves ferimentos ou morte. Danger: PERICOLO Le indicazioni di pericolo forniscono informazioni per evitare situazioni o condizioni che...
  • Page 16 Regulatory Information and Safety Precautions Routine Maintenance March 2011...
  • Page 17: Chapter 2: New In This Release

    Chapter 2: New in this release There are no new changes described in Avaya Ethernet Routing Switch 8800/8600 Routine Maintenance, NN46205-312 for Release 7.1. Routine Maintenance March 2011...
  • Page 18 New in this release Routine Maintenance March 2011...
  • Page 19: Chapter 3: Introduction

    • the significance and the performance of the equipment • how often configuration changes are made • if there are dramatic changes in traffic patterns For information about the organization of the technical documentation, see Avaya Ethernet Routing Switch 8800/8600 Documentation Roadmap, NN46205-103. Navigation •...
  • Page 20 Introduction Routine Maintenance March 2011...
  • Page 21: Chapter 4: Fan Tray And Cooling Module Cleaning

    Chapter 4: Fan Tray and Cooling Module cleaning This chapter describes how to clean the fans in the Avaya Ethernet Routing Switch 8800/8600 fan trays and cooling modules. Clean the fans to ensure proper air flow for cooling, thereby ensuring the longevity and optimal performance of the equipment.
  • Page 22 Caution: Risk of equipment damage Avaya recommends that you power down the chassis before you clean fans and vents. If you operate the system for more than five minutes without a operational fan tray, equipment damage can occur.
  • Page 23: Cleaning Fans Trays Or Cooling Modules In An 8006 Or 8010 Chassis

    Cleaning fans trays or cooling modules in an 8006 or 8010 chassis Grasp the fan tray at the middle of the front panel and be careful to keep your fingers out of the fan blades. 2. Wait 10 seconds for the fans to stop turning. Pull the fan tray out of the chassis. 3.
  • Page 24 Fan Tray and Cooling Module cleaning A single 8006 fan tray or 8606CMHS cools the 8006 chassis. The high-speed fan tray or cooling module of the 8006 chassis is called 8006CMHS fan tray or cooling module. The 8006 chassis fan tray and 8006CMHS cooling module are installed on the right side of the chassis. Figure 2: 8006 fan tray on page 24 illustrates the fan tray for the 8006 chassis.
  • Page 25 Cleaning fans trays or cooling modules in an 8006 or 8010 chassis Figure 3: 8006CMHS cooling module Two 8010 fan trays or 8010CMHS cool the 8010 chassis. Figure 4: 8010 fan tray on page 26 illustrates the fan tray for the 8010 chassis. Routine Maintenance March 2011...
  • Page 26 Fan Tray and Cooling Module cleaning Figure 4: 8010 fan tray Figure 5: 8010CMHS cooling module on page 27 illustrates the cooling module for the 8010 chassis. Routine Maintenance March 2011...
  • Page 27 Caution: Risk of equipment damage Avaya recommends that you power down the chassis before you clean fans and vents. If you oprate a system for more than five minutes without a operational fan tray or cooling module, equipment damage can occur.
  • Page 28 Fan Tray and Cooling Module cleaning Warning: Risk of personal injury Grasp the fan tray or cooling module at the middle of the front panel, and be careful to keep your fingers out of the fan blades. 2. Wait 10 seconds for the fans to stop turning. Pull the fan tray or cooling module from the chassis.
  • Page 29: Cleaning Fans In An 8010Co Chassis

    Caution: Risk of equipment damage Avaya recommends that you power down the chassis before you clean fans and vents. If you operate a system for more than five minutes without a operational fan tray or cooling module, equipment damage can occur.
  • Page 30 Fan Tray and Cooling Module cleaning 5. Insert the plug into the ground port on the front of the chassis. 6. Turn the fan tray lock to unlock position. 7. Press upwards on the inside of the handle to disengage the fan tray from the chassis back panel and pull it from the chassis.
  • Page 31 Cleaning fans in an 8010co chassis Important: If the system power is on, the second fan tray immediately accelerates to high speed and indicates a fault condition. 8. Wait 10 seconds for the fans to stop turning. Pull the fan tray from the chassis. 9.
  • Page 32 Fan Tray and Cooling Module cleaning 11. Turn the fan tray lock to the lock position. Routine Maintenance March 2011...
  • Page 33: Chapter 5: Chassis Slots And Backplane Cleaning

    Chapter 5: Chassis slots and backplane cleaning This chapter describes how to clean the Ethernet Routing Switch 8800/8600 chassis slots and backplane. Clean the chassis slots and backplane to ensure proper air flow for cooling, thereby ensuring the longevity and optimal performance of the equipment.
  • Page 34 Chassis slots and backplane cleaning Figure 7: Cleaning slots and backplane procedures task flow Routine Maintenance March 2011...
  • Page 35: Module Removal And Switch Behavior Considerations

    Cleaning slots and backplane procedures navigation Cleaning slots and backplane procedures navigation • Module removal and switch behavior considerations on page 35 • Job aid: Avoiding ESD on page 36 • Removing a filler panel on page 36 • Removing a module on page 37 •...
  • Page 36: Sf/Cpu Modules

    To prevent electrostatic discharge damage when you work with the Ethernet Routing Switch 8800/8600, place each module on a grounded antistatic mat until you are ready to install it. If you do not have an antistatic mat, wear a discharge leash or wrist strap to free yourself of static before you touch a module.
  • Page 37: Removing A Module

    Removing a module Procedure steps 1. Using a Phillips screwdriver, loosen the two captive screws that fasten the filler panel to the chassis as shown the following figures. The first figure shows the 8003-R, 8006, and 8010 chassis and the second figure shows the 8010co chassis.
  • Page 38 Caution: Rick of electromagnetic interference Do not operate the Ethernet Routing Switch 8800/8600 with an empty module slot. If you need to replace a failed module and you do not yet have a replacement module, leave the failed module installed or install a filler panel.
  • Page 39: Installing A Filler Panel

    Installing a filler panel Installing a filler panel After you clean the chassis slots or backplane you must install a filler panel or module in the slot. To maintain proper airflow and cooling, always cover unused module slots and power supply bays with filler panels.
  • Page 40: Installing A Module

    3. Tighten the two screws with a Phillips screwdriver. Installing a module Install an Ethernet Routing Switch 8800/8600 module with the power on or off. If you install a module in the same chassis slot where the same type of module was previously installed, the previous configuration is maintained for that module in that slot.
  • Page 41: Job Aid: Installing A Module

    Installing a module After you install the modules, you can connect console equipment and network cables. For instructions, see Avaya Ethernet Routing Switch 8800/8600 Installation — Modules, NN46205-304. Job aid: Installing a module Figure 8: Installing a module: 8003-R, 8006, and 8010 chassis...
  • Page 42: Job Aid: Seating The Backplane Connectors

    Chassis slots and backplane cleaning Job aid: Seating the backplane connectors Figure 10: Seating the backplane connectors: 8003-R, 8006, and 8010 chassis Figure 11: Seating the backplane connectors: 8010co chassis Routine Maintenance March 2011...
  • Page 43: Job Aid: Securing The Module In The Chassis

    Installing a module Job aid: Securing the module in the chassis Figure 12: Securing the module in the chassis: 8003-R, 8006, and 8010 chassis Figure 13: Securing the module in the chassis: 8010co chassis Routine Maintenance March 2011...
  • Page 44 Chassis slots and backplane cleaning Routine Maintenance March 2011...
  • Page 45: Chapter 6: Ac Power Supply Replacement

    Caution: Risk of equipment damage To maintain proper cooling, never operate the Avaya Ethernet Routing Switch 8800/8600 chassis with an empty power supply bay. If you are replacing a failed power supply and you do not have a power filler panel, leave the failed power supply installed until a replacement power supply is available.
  • Page 46 AC power supply replacement Figure 14: AC power supply replacement procedures task flow AC power supply replacement procedures navigation • Removing the AC power supply on page 47 • Installing the AC power supply on page 51 Routine Maintenance March 2011...
  • Page 47: Removing The Ac Power Supply

    Removing the AC power supply Removing the AC power supply When you remove a power supply, the LED on the power supply turns off, and the Ethernet Routing Switch 8800/8600 chassis automatically redistributes the load to the remaining power supplies. Important: To remove a power supply from the 8010co chassis with bezel model 312096-A installed, you must remove the bottom front bezel.
  • Page 48 AC power supply replacement Job aid: AC power supply power switch off Figure 15: AC power supply power switch off: 8010co chassis Figure 16: AC power supply power switch off: 8006 and 8010 chassis Figure 17: AC power supply power switch off: 8003-R chassis Routine Maintenance March 2011...
  • Page 49 Removing the AC power supply Job aid: Disconnect power cord Figure 18: Disconnecting the power cord: 8010co chassis Figure 19: Disconnecting the power cord: 8006 and 8010 chassis Figure 20: Disconnecting the power cord: 8003-R chassis Routine Maintenance March 2011...
  • Page 50 AC power supply replacement Job aid: Loosen the retaining screws Figure 21: Loosening the retaining screws: 8010co chassis Figure 22: Loosening the retaining screws: 8006 and 8010 chassis Figure 23: Loosening the retaining screws: 8003-R chassis Routine Maintenance March 2011...
  • Page 51: Installing The Ac Power Supply

    Figure 24: Removing the power supply: 8010co chassis Figure 25: Removing the power supply: 8003R, 8006 and 8010 chassis Installing the AC power supply Install the AC power supply to the input power source of the Avaya Ethernet Routing Switch 8800/8600. Voltage:...
  • Page 52 • Remove the filler panel from the power bay if required. Save the power filler panel in case you need to operate the Ethernet Routing Switch 8800/8600 chassis with a power supply removed. Use the following procedure to install the AC power supply. For more information about installing the AC power supply, see the job aids following the procedure.
  • Page 53 Installing the AC power supply Job aid: AC power supply installation Figure 26: Installing the AC power supply: 8010co chassis Routine Maintenance March 2011...
  • Page 54 AC power supply replacement Figure 27: Installing the AC power supply: 8006 and 8010 chassis Routine Maintenance March 2011...
  • Page 55 Installing the AC power supply Figure 28: Installing the AC power supply: 8003-R chassis Job aid: Tighten the retaining screws Figure 29: Tightening the retaining screws: 8010co chassis Routine Maintenance March 2011...
  • Page 56 AC power supply replacement Figure 30: Tightening the retaining screws: 8006 and 8010 chassis Figure 31: Tightening the retaining screws: 8003-R chassis Job aid: Power cord connection The 8005DI AC power supply has two connectors for the power cord. Figure 32: 8005DI Power Supply cord on page 57 shows the two power cord connectors for the 8005DI power supply.
  • Page 57 Installing the AC power supply Figure 32: 8005DI Power Supply cord Figure 33: Connecting the power cord: 8010co chassis Routine Maintenance March 2011...
  • Page 58 AC power supply replacement Figure 34: Connecting the power cord: 8003R, 8006 and 8010 chassis Job aid: AC power supply switch on Figure 35: AC power supply power switch on: 8010co chassis Figure 36: AC power supply power switch on: 8003R, 8006 and 8010 chassis Routine Maintenance March 2011...
  • Page 59: Chapter 7: Dc Power Supply Replacement

    Replace the DC power supply if it is not functioning properly. When you remove a power supply, the LED on the power supply turns off, and the Avaya Ethernet Routing Switch 8800/8600 chassis automatically redistributes the load to the remaining power supplies.
  • Page 60 DC power supply replacement Figure 37: DC power supply replacement procedures task flow DC power supply replacement procedures navigation • Removing the DC power supply on page 61 • Installing the 8004DC and 8005DC power supply on page 66 • Installing the 8005DI DC power supply on page 73 Routine Maintenance...
  • Page 61: Removing The Dc Power Supply

    Removing the DC power supply Removing the DC power supply Use the following procedure to remove the DC power supply. For more information about removing the DC power supply, see the job aids following the procedure. Procedure steps Caution: To maintain proper cooling, never operate the chassis with an empty power supply bay. If you replace a failed power supply and you have no power filler panel, leave the failed power supply installed until a replacement power supply is available.
  • Page 62 DC power supply replacement Before you continue with this procedure, ensure that the DC power source is switched off. 4. Loosen the retaining screws on the power supply. See Job aid: Loosening the retaining screws on the DC power supply on page 64.
  • Page 63 Removing the DC power supply 9. Disconnect the earth ground lead from the ground stud on the power supply. Routine Maintenance March 2011...
  • Page 64 DC power supply replacement 10. Slide the power supply all the way out of the chassis and set it aside. See Removing the DC power supply on page 61. Job aid: Loosening the retaining screws on the DC power supply Figure 38: Loosening the retaining screws on the DC power supply: 8010co chassis Routine Maintenance March 2011...
  • Page 65 Removing the DC power supply Figure 39: Loosening the retaining screws on the DC power supply: 8003R, 8006 and 8010 chassis Job aid: Disconnecting the DC power supply from the backplane Figure 40: Disconnecting the DC power supply from the backplane: 8010co chassis Figure 41: Disconnecting the DC power supply from the backplane: 8003R, 8006 and 8010 chassis Routine Maintenance...
  • Page 66: Installing The 8004Dc And 8005Dc Power Supply

    Prerequisites If you install a power supply in the 8010co chassis with bezel model 312096-A installed, you must remove the bottom front bezel. For instructions, see Avaya Ethernet Routing Switch 8800/8600 Installation — DC Power Supply, NN46205-307. Procedure steps Important: If you replaced bezel 312096-A with the modified bezel model 321325-A, you do not need to remove the bezel.
  • Page 67 Caution: Save the power filler panel in case you need to operate the Ethernet Routing Switch 8800/8600 chassis with a power supply removed. 3. If you are replacing a failed power supply, remove the failed DC power supply. 4. Grasp the handle of the new power supply.
  • Page 68 DC power supply replacement Either +VDC or –VDC can be referenced to the frame ground for +48 VDC (nominal) or –48 VDC (nominal) applications. 8. Make sure that the +DC cable is always connected to the positive terminal and the –DC cable is always connected to the negative terminal.
  • Page 69 Important: Due to the N+1 power sharing architecture, if your chassis contains two or three non-redundant power supplies, Avaya recommends that you turn on the power supplies simultaneously. If you wait longer to turn on the supplies, the power supplies shut off within 7 seconds. To correct this condition, turn off the power...
  • Page 70 DC power supply replacement supplies for 2 minutes, and then simultaneously turn on the power supplies again. 21. If the LED on the power supply does not turn on, contact the Avaya Technical Solutions Center. Job aid: Inserting the DC power supply...
  • Page 71 Installing the 8004DC and 8005DC power supply Job aid: DC power supply input and ground stud location Figure 45: 8004DC power supply input and ground stud location Figure 46: 8005DC power supply input and ground stud location Routine Maintenance March 2011...
  • Page 72 DC power supply replacement Job aid: Attaching the earth ground lead to the ground stud Figure 47: Attaching the earth ground lead to the ground stud (8004) Figure 48: Attaching the earth ground lead to the ground studs (8005) Routine Maintenance March 2011...
  • Page 73: Installing The 8005Di Dc Power Supply

    Figure 51: Tightening the retaining screws on the DC power supply: 8003-R chassis Installing the 8005DI DC power supply Install the 8005DI DC power supply to the DC input power source of the Avaya Ethernet Routing Switch 8800/8600. Routine Maintenance...
  • Page 74 2. Remove the filler panel from the power bay if necessary. Caution: Save the power filler panel in case you need to operate the Ethernet Routing Switch 8800/8600 chassis with a power supply removed. 3. Grasp the handle of the new power supply. Routine Maintenance...
  • Page 75 Installing the 8005DI DC power supply 4. Push the new power supply partway into the bay, leaving the terminal block at the side of the power supply exposed. 5. Use a Phillips screwdriver to remove the screw that secures the plastic safety cover to the power supply and remove the cover.
  • Page 76 DC power supply replacement Either +VDC or –VDC can be referenced to the frame ground for +48 VDC (nominal) or –48 VDC (nominal) applications. 7. Make sure that the +DC cable is always connected to the positive terminal and the –DC cable is always connected to the negative terminal.
  • Page 77 Installing the 8005DI DC power supply • lock washer • hex nut 9. Attach the positive voltage lead to the positive terminal on the power supply and insert a lock washer between the crimp lug and each hex nut. 10. Attach the negative voltage lead to the negative terminal on the power supply to insert a lock washer between the crimp lug and each hex nut.
  • Page 78 DC power supply replacement 16. Attach the positive and negative terminal leads to the DC input power source according to the proper safety and technical specifications for your 48 V power distribution system. 17. Turn the DC input power source on or reset the power source circuit breaker to provide power to the power supply.
  • Page 79 7 seconds. To correct this condition, turn off the power supplies for 2 minutes, and then simultaneously turn on the power supplies again. 19. If the LED on the power supply does not turn on, contact the Avaya Technical Solutions Center. Routine Maintenance...
  • Page 80 DC power supply replacement Routine Maintenance March 2011...
  • Page 81: Chapter 8: Fan Tray And Cooling Module Replacement

    Chapter 8: Fan tray and Cooling module replacement This chapter describes how to replace the fan tray or the cooling module in the Avaya Ethernet Routing Switch 8800/8600. Replace the fan tray or the cooling module if they not functioning properly. Replacement takes 2 to 5 minutes.
  • Page 82 Fan tray and Cooling module replacement Figure 52: Fan tray and Cooling module replacement procedures Fan tray and Cooling module replacement navigation • Replacing the fan tray in an 8003-R chassis on page 83 • Replacing the fan tray or cooling module in an 8006 or 8010 chassis on page 84 •...
  • Page 83: Replacing The Fan Tray In An 8003-R Chassis

    Replacing the fan tray in an 8003-R chassis Replacing the fan tray in an 8003-R chassis Replace the fan tray in the 8003-R chassis when the existing fan tray fails to work. You can replace the fan tray in the 8003-R chassis with the power on or off. Procedure steps 1.
  • Page 84: Replacing The Fan Tray Or Cooling Module In An 8006 Or 8010 Chassis

    Fan tray and Cooling module replacement 4. Tighten the captive screws to fasten the fan tray to the chassis. 5. With the chassis power on, verify that the green status LED is illuminated. Replacing the fan tray or cooling module in an 8006 or 8010 chassis Replace the fan tray or cooling module when the existing a fan tray or cooling module fails to work.
  • Page 85 Replacing the fan tray or cooling module in an 8006 or 8010 chassis 2. Wait 10 seconds for the fans to stop turning. Pull the fan tray or cooling module from the chassis. Caution: Grasp the fan tray or cooling module at the middle of the front panel. Be careful to keep your fingers away from the fan blades.
  • Page 86: Replacing The Fan Tray In An 8010Co Chassis

    Fan tray and Cooling module replacement Replacing the fan tray in an 8010co chassis The 8010co chassis contains two fan trays. Replace the fan tray if it fails to work. Procedure steps Important: You can replace a fan tray in the 8010co chassis with the power on or off. Caution: Electrostatic discharge can damage hardware.
  • Page 87 Replacing the fan tray in an 8010co chassis 6. Turn the fan tray lock to unlock position. 7. Press upwards on the inside of the handle to disengage the fan tray from the chassis back panel, and pull it from the chassis. 8.
  • Page 88 Fan tray and Cooling module replacement 9. Slide the new fan tray into the chassis until the connectors at the rear of the fan tray engage. If the chassis is on, the fans start turning after the fan tray connectors are fully engaged.
  • Page 89: Chapter 9: I/O Module Replacement

    Replace the I/O module for optimum performance if it is not functioning properly. I/O module replacement procedures This task flow shows you the sequence of procedures you perform to replace the Input Output (I/O) module of the Avaya Ethernet Routing Switch 8800/8600. Routine Maintenance March 2011...
  • Page 90 I/O module replacement Figure 53: I/O module replacement procedures Routine Maintenance March 2011...
  • Page 91: Removing A Module

    SF/CPU module and you remove that module, the switch does not operate. • Ensure that traffic is not traversing the module. First, disable the module. For further instructions, see Avaya Ethernet Routing Switch 8800/8600 Configuration — Ethernet Modules, NN46205-503. Warning: Risk of eye injury Fiber optic equipment can emit laser or infrared light that can injure your eyes.
  • Page 92 I/O module replacement Do not operate the Ethernet Routing Switch 8800/8600 with an empty module slot. If you need to replace a failed module and you do not yet have a replacement module, leave the failed module installed or install a filler panel.
  • Page 93: Installing A Module

    Installing a module Installing a module Install an Ethernet Routing Switch 8800/8600 module with the power on or off. If you install a module in the same chassis slot where the same type of module was previously installed, the previous configuration is maintained for that module in that slot. Otherwise, a module installed in an Ethernet Routing Switch 8800/8600 chassis is reset to factory defaults.
  • Page 94 I/O module replacement Job aid: Hot swapping an I/O module Use this procedure to hot swap an Ethernet Routing Switch 8800/8600 I/O module. You can use this procedure when you upgrade to the latest modules. Caution: Risk of traffic loss or corruption Do not hot swap or insert modules in a switch while the switch boots.
  • Page 95: Chapter 10: 8010Co Chassis Air Filter Replacement

    Chapter 10: 8010co chassis air filter replacement This chapter describes the procedures to install or replace an air filter in the 8010co chassis of an Avaya Ethernet Routing Switch 8800/8600. To maintain proper operation of the 8010co chassis, you must periodically replace the air filter in the chassis.
  • Page 96: 8010Co Chassis Air Filter Installation Procedures

    8010co chassis air filter replacement 8010co chassis air filter installation procedures This task flow shows you the sequence of procedures you perform to install the air filter in the 8010co chassis. Figure 54: 8010co chassis air filter installation procedures task flow Routine Maintenance March 2011...
  • Page 97: Removing The Air Bezel

    8010co chassis air filter installation procedures 8010co chassis air filter installation navigation • Removing the air bezel on page 97 • Installing the air filter on page 99 • Mounting the air bezel on page 100 Removing the air bezel Remove the air bezel from the chassis to access the air filter.
  • Page 98 8010co chassis air filter replacement 4. To remove air bezel 321325-A, lift the bezel from behind the return flange on the chassis. The following figure shows how to remove the bottom bezel 321325-A. Routine Maintenance March 2011...
  • Page 99: Installing The Air Filter

    8010co chassis air filter installation procedures Installing the air filter This procedure provides instructions to install an air filter in the 8010co chassis. Important: You can install the air filter while the switch continues to operate. Prerequisites Ensure that the air filter is free of contaminants. Procedure steps 1.
  • Page 100: Mounting The Air Bezel

    8010co chassis air filter replacement The following figure shows how to install the air filter in the 8010co chassis. 3. Apply even force at both the corners and gently slide the new filter into the housing. 4. Replace the bottom front of the bezel. Mounting the air bezel This procedure provides instructions to mount the air bezel in the 8010co chassis.
  • Page 101 8010co chassis air filter installation procedures Mounting air bezel 312096-A Procedure steps 1. Set the two bezel notches (on either end of the bottom of the bezel) into the two tabs at the bottom of the chassis. The following figure shows how to mount the bottom bezel 312096-A. 2.
  • Page 102: Air Filter Maintenance

    To maintain proper operation of the 8010co chassis, you must periodically replace the air filter in the chassis. How often you need to replace the air filter depends on the cleanliness at the installation site. Contact Avaya for replacement air filters (part number 312194-A). Routine Maintenance...
  • Page 103: Compliance Information

    43.68 cm (17.20 in.) Replacement aids Avaya recommends that you replace the air filter in the 8010co chassis every three months. After you install the first 8010co chassis at your site, inspect the air filter every month until you establish a regular replacement schedule.
  • Page 104 8010co chassis air filter replacement Routine Maintenance March 2011...
  • Page 105: Chapter 11: Inspecting Equipment

    Chapter 11: Inspecting equipment Perform the following procedures on a regular basis for optimum performance. • Securely attach the blank faceplates to the chassis and ensure the fans are running. • Allow proper ventilation to the switch. • Seat all the modules securely in the backplane and attach to the chassis firmly. •...
  • Page 106: Checking Power Supply Leds

    1. Power on the chassis. Verify that the power output LED for each power supply turns green. The 8005 DC power supply requires the removal and the replacement of the 312096-A bezel to view the power supply LEDs. For more information, see Avaya Ethernet Routing Switch 8800/8600 Installation — DC Power Supply, NN46205-307.
  • Page 107 Checking power supply LEDs The following figure shows the location of the LED on the 8004AC, 8005AC, and 8005 DI DC power supplies. 2. Verify that the power supply status LEDs and the fan LED on the 8692 SF/CPU or 8895 SF/CPU (as shown in the following figure) modules illuminate green.
  • Page 108: Checking Fan Tray Leds

    Inspecting equipment State Meaning No output is present. On (green) Power supply output is normal. Checking fan tray LEDs Table 2: Fan tray LED for 8003-R, 8006, 8010 chassis on page 108 describes the fan tray LEDs on 8003-R, 8006 and 8010 chassis. If a fan fails in a fan tray or cooling module, the Fan 1 or Fan 2 LED on the switch fabric module lights amber.
  • Page 109: Chapter 12: Translations Of Safety Messages

    Chapter 12: Translations of safety messages Class A product caution statement Caution: This device is a Class A product. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users are required to take appropriate measures necessary to correct the interference at their own expense.
  • Page 110: Electrostatic Discharge Caution Statement

    Translations of safety messages Este dispositivo é um produto Classe A. Operar este equipamento em uma área residencial provavelmente causará interferência prejudicial; neste caso, espera-se que os usuários tomem as medidas necessárias para corrigir a interferência por sua própria conta. Caution: ATTENZIONE Questo dispositivo è...
  • Page 111: Empty Power Supply Bay Caution Statement

    Empty power supply bay caution statement Caution: To maintain proper cooling, never operate the Ethernet Routing Switch 8800/8600 with an empty power supply bay. If you are replacing a failed power supply and you do not have a power filler panel, leave the failed power supply installed until a replacement power supply is available.
  • Page 112: Electromagnetic Interference Caution Statement

    Caution: Risk of electromagnetic interference Do not operate the Ethernet Routing Switch 8800/8600 with an empty module slot. If you need to replace a failed module and you do not have a replacement module, leave the failed module installed or install a filler panel. Operating the switch with an empty module slot can cause electromagnetic interference to other equipment in the area.
  • Page 113 CUIDADO Risco de interferência eletromagnética Não opere o Ethernet Routing Switch 8800/8600 com um slot de módulos vazio. Se for preciso substituir um módulo com defeito e você não tiver um módulo de substituição, deixe o módulo com defeito instalado ou instale um painel de preenchimento. Trabalhar no comutador com um slot de módulos vazio pode causar interferência eletromagnética a outro...
  • Page 114: Fan Tray Warning Statement

    Translations of safety messages Non utilizzare il Ethernet Routing Switch 8800/8600 con un alloggiamento modulo vuoto. Se è necessario sostituire un modulo guasto ma non si dispone di un modulo per la sostituzione, lasciare installato quello guasto o installare un pannello di riempimento. L'uso dell'interruttore con l'alloggiamento modulo vuoto può...
  • Page 115: Connection Cable Caution Statement

    Connection cable caution statement Segure a bandeja do ventilador no meio do painel frontal e tenha cuidado para não colocar os dedos nas lâminas do ventilador. Warning: AVVISO Rischio di lesioni personali Afferrare il vassoio del ventilatore nella parte centrale del pannello frontale e prestare attenzione a non toccare le lame.
  • Page 116 Translations of safety messages El equipo de fibra óptica puede emitir una luz láser o infrarroja que dañe sus ojos. Nunca mire un puerto de fibra óptica o conector. Siempre asuma que los cables de fibra óptica están conectados a una fuente de luz. Warning: AVISO O laser pode causar ferimentos no olho...
  • Page 117: Chapter 13: Customer Service

    Chapter 13: Customer service Visit the Avaya Web site to access the complete range of services and support that Avaya provides. Go www.avaya.com or go to one of the pages listed in the following sections. Navigation • Getting technical documentation on page 117 •...
  • Page 118: Getting Technical Support From The Avaya Web Site

    Customer service Getting technical support from the Avaya Web site The easiest and most effective way to get technical support for Avaya products is from the Avaya Technical Support Web site at www.avaya.com/support. Routine Maintenance March 2011...

This manual is also suitable for:

8600

Table of Contents