Configuring SNMP notifications
The SNMP notification table (snmpNotifyTable) is preconfigured and nonconfigurable in the
ACLI.
Configuring an SNMP host
Configure an SNMP host so that the switch can forward SNMP traps to a host for monitoring.
You can use SNMPv1, SNMPv2c, or SNMPv3.
Prerequisites
• Access Global Configuration mode.
Procedure steps
1. Configure an SNMPv1 host by entering the following command:
2. Configure an SNMPv2c host by entering the following command:
3. Configure an SNMPv3 host by entering the following command:
4. Ensure that the configuration is correct:
Troubleshooting
snmp-server host <WORD 1-256> port <1-65535> v1 <WORD 1-32>
[filter <WORD 1-32>] [target-name <WORD 1-32>]
<WORD 1-256> specifies either an IPv4 or IPv6 address. port <1-65535>
specifies the host server port number.
snmp-server host <WORD 1-256> port <1-65535> v2c <WORD 1-32>
[inform [mms <0-2147483647>] [retries <0-255>] [timeout
<0-2147483647>]] [filter <WORD 1-32>] [target-name <WORD
1-32>]
snmp-server host <WORD 1-256> port <1-65535> v3
{noAuthnoPriv|authNoPriv|AuthPriv} <WORD 1-32> [inform
[retries <0-255>] [timeout <0-2147483647>]] [filter <WORD
1-32>] [target-name <WORD 1-32>]
show snmp-server host
Configuring SNMP notifications
July 2013
313