SP3-XXX (Process)

3-005
[TD Initial] TD Sensor Initialization ([Color])
3-005-1 [K]
3-005-2 [Y]
3-005-3 [M]
3-005-4 [C]
3-005-5 [All Color]
3-005-6
Result
Displays the developer initialization result.
All colors are displayed. Values is displayed in the order K Y C M.
e.g., 1 1 2 1: Initialization of Cyan failed but the others succeeded
See the troubleshooting section for details.
3-006
[Vcnt Initial] Vcnt Initial Setting Display ([Color])
Displays the initial Vcnt value.
3-006-1 [K]
3-006-2 [Y]
3-006-3 [M]
3-006-4 [C]
3-007
[Vcnt Current] Vcnt Current Value Display ([Color])
Displays the current Vcnt value.
3-007-1 [K]
3-007-2 [Y]
3-007-3 [M]
3-007-4 [C]
3-008
[Humidity]
3-008-1
Humidity
Displays the humidity measured by the humidity/temperature sensor.
SM
Initializes the developer. DFU
*BCU
[ 1 to 9 / - / - ]
1: Success
2 to 9: Failure
*BCU
[ 0 to 240 / 100 / 0.1/step ]
*BCU
*BCU
*BCU
*BCU
[ 0 to 240 / - / 0.1/step ]
*BCU
*BCU
*BCU
*BCU
[ 0 to 100 / - / 1/step ]