continuous-reboot-prevention

Overview
Use this command to enable and to configure the continuous reboot prevention
feature. Continuous reboot prevention allows the user to configure the time
period during which reboot events are counted, the maximum number of times
the switch can reboot within the specified time period, referred to as the threshold,
and the action to take if the threshold is exceeded.
Use the no variant of this command to disable the continuous reboot prevention
feature or to return the period, threshold and action parameters to the defaults.
continuous-reboot-prevention enable
Syntax
continuous-reboot-prevention [period <0-604800>] [threshold
<1-10>] [action [linkdown|logonly|stopreboot]]
no continuous-reboot-prevention enable
no continuous-reboot-prevention [period] [threshold] [action]}
Default
Continuous reboot prevention is disabled by default. The default period value is
600, the default threshold value is 1 and the default action is linkdown.
Mode
Global Configuration
Usage notes
Note that user-initiated reboots via the CLI, and software version
auto-synchronization reboots, are not counted toward the threshold value.
C613-50631-01 Rev A
C
ONITORING
OMMANDS
Parameter
Description
enable
Enable the continuous reboot prevention feature.
period
Set the period of time in which reboot events are counted.
<0-604800>
threshold
Set the maximum number of reboot events allowed in the specified
period.
<1-10>
action
Set the action taken if the threshold is exceeded.
linkdown
logonly
stopreboot
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Period value in seconds. The default is 600.
Threshold value. The default is 1.
Reboot procedure continues and all switch
ports stay link-down. The reboot event is
logged. This is the default action.
Reboot procedure continues normally and the
reboot event is logged.
Reboot procedure stops until the user enters
the key "c" via the CLI. Normal reboot procedure
then continues and the reboot event is logged.